Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
Yes - Zendure SuperBase V4600 has enough running and surge power for the Slow Cooker. Target ~330W running / 330W surge; the generator provides 3800W / 3800W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
330W required -> 3,800W available (3,470W headroom)
Startup peak with safety buffer applied.
330W required -> 3,800W available (3,470W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 10.8h
Device profile reference: up to 6h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Crock-Pot 7-Quart Manual Slow Cooker (SAP_2131381) (300W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Crock-Pot 6-Quart Cook and Carry (SCCPVL610SA) | 240W | 240W | Safe | ~13.4h | OEM Verified |
Show expert analysisTechnical: **Running load:** 240 W. **Surge:** 240 W (no inrush spike). **Voltage:** 120 V AC required. Resistive heating element draws steady current with no motor or compressor startup transient. Field note: Verify power station AC inverter capacity exceeds 240 W continuous rating. Reserve at least 20% headroom (300 W minimum inverter rating) for thermal stability during extended runtime. Can I run this slow cooker on a portable power station all day? Only if your power source can supply at least 240W continuous and 240W surge at 120V. | |||||
| Crock-Pot 7-Quart Manual Slow Cooker (SAP_2131381) | 300W | 300W | Safe | ~10.8h | OEM Verified |
Show expert analysisTechnical: **Running load:** 300 W. **Surge:** 300 W (resistive heating element, no motor startup). **Voltage:** 120 V AC required. Power station must sustain 300 W continuous output at 120 V for safe operation. Field note: Verify power station rated capacity exceeds 1800 Wh if running the full daily cycle. Add 10-15% margin for inverter efficiency losses. Can I cook an 8-hour recipe on a single charge? Only if your power source can supply at least 300W continuous and 300W surge at 120V. It depends on the power station's usable capacity. An 8-hour cook cycle requires 2400 Wh minimum, plus inverter overhead. Verify your unit's rated watt-hours before planning extended recipes. | |||||
| Crock-Pot 4.5-Quart Manual Slow Cooker (SAP_2131365) | 210W | 210W | Safe | ~15.4h | OEM Verified |
Show expert analysisTechnical: **Running load:** 210 W. **Surge:** 210 W (resistive heating element, no inrush). **Voltage:** 120 V AC required. Power station must deliver clean 120 V output and at least 210 W continuous capacity. Field note: Verify power station capacity exceeds 1260 Wh if running a full daily cook cycle on battery alone. Leave 15 percent headroom for inverter efficiency loss. Can I run this slow cooker for 8 hours on a 1500 Wh power station? Only if your power source can supply at least 210W continuous and 210W surge at 120V. | |||||
This unit ranks #24 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for Slow Cooker.
Fit class uses buffered needs (running and surge) for this device.
All-Day Slow Cooking
Select Your Model:
Free Tools
At 3800W continuous, the SuperBase V4600 handles most residential loads comfortably. The conservative surge rating (no hardware surge above continuous) means high-inrush devices like air compressors and well pumps may trigger protection cutoffs โ always check surge requirements. The 4608Wh base capacity provides 12+ hours for moderate loads, and the modular B4600 satellite system scales to 23kWh for multi-day outages. Solar input accepts up to 1500W (150V ร 10A) via XT90, though the single-port design limits parallel panel configurations.
The SuperBase V4600 uses LiFePO4 chemistry rated for 3,000+ cycles. The GridFlow 2.0 system provides 1ms UPS switchover, making it suitable for sensitive medical and computing equipment. The 120V/240V selective output supports both standard and high-voltage appliances. Source: Zendure official US product page (manufacturer documentation).
Keep your Slow Cooker running with solar โข MPPT: 12โ 150V โข Max: 1500W
Smart Value 400W Panel
Adapter required: MC4 -> XT90.
Smart Value 400W Panel
Adapter required: MC4 -> XT90.
Yes. The Zendure SuperBase V4600 provides 3800W running / 3800W surge. The Slow Cooker needs 330W / 330W (including 10% buffer). That leaves 3470W of running headroom and 3470W of surge margin.
Approximately 10.8 hours, based on the Slow Cooker's 300W draw and the Zendure SuperBase V4600's 4608Wh capacity (70% usable after real-world losses).
With 2565W allocated to the Slow Cooker, the Zendure SuperBase V4600 still has ~175W of margin. These devices could run simultaneously:
Efficiency Hack: Large appliances like the Slow Cooker cycle on and off. To maximize the 10.8 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the Slow Cooker
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Crock-Pot 7-Quart Manual Slow Cooker (SAP_2131381) (300W). Surge = running (resistive heating element โ no motor inrush).
Zendure SuperBase V Official Product Page (US) โ full specifications
Similar-output alternatives you can compare side by side.