Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
This pairing clears the safety headroom. Required ~1601W running and 4803W surge; the Pecron E3600LFP is rated 3600W / 7000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,601W required -> 3,600W available (1,999W headroom)
Startup peak with safety buffer applied.
4,803W required -> 7,000W available (2,197W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 1.5h
Device profile reference: up to 1h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Shop-Vac SVX2 (12-Gal, 5.5 HP Peak) (4,176W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| DeWalt DXV10P (10-Gal, 5.5 HP, 2-Stage Quiet) | 1,200W | 3,600W | Safe | ~1.8h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 1200W from OEM nameplate (10A ร 120V). **Estimated startup surge:** 3600W at 3x running (motor-load multiplier โ no OEM starting watts published). **Voltage:** 120V AC. 2-stage motor, 90 CFM airflow, 73 dB noise rating โ quietest in this set. Field note: The DXV10P is the most power-station-friendly shop vac in this set. At 1200W running and an estimated 3600W surge, it works with most power stations rated 2000W+ with adequate surge capacity. The 2-stage motor runs quieter (73 dB) and may have lower actual inrush than single-stage models, though no OEM data confirms this. Can a portable power station run the DeWalt DXV10P? Only if your power source can supply at least 1200W continuous and approximately 3600W surge at 120V. The motor startup surge is the main challenge, not the running watts. | |||||
| Vacmaster Beast VFB511B (5-Gal, 6 HP Peak, Compact) | 1,320W | 3,960W | Safe | ~1.6h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 1320W from OEM specs (11A ร 120V). **Estimated startup surge:** 3960W at 3x running (motor-load multiplier โ no OEM starting watts published). **Voltage:** 120V AC. Single-stage motor, 102 CFM airflow, 320 Air Watts, 82 in. water lift. Field note: The Beast packs the most suction power per pound in this set โ 102 CFM from a 12 lb unit. At 1320W running it draws 10% more than the DeWalt but delivers 13% more airflow. The compact 5-gallon tank makes it portable but limits continuous use on large jobs. Is the Vacmaster Beast harder to run on a power station than the DeWalt? Slightly โ 1320W versus 1200W running, with an estimated 3960W versus 3600W surge. Both need a power station with at least 2000W continuous and 4000W+ surge for reliable startup. | |||||
| Shop-Vac SVX2 (12-Gal, 5.5 HP Peak) | 1,392W | 4,176W | Safe | ~1.5h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 1392W from OEM specs (11.6A ร 120V). **Estimated startup surge:** 4176W at 3x running (motor-load multiplier โ no OEM starting watts published). **Voltage:** 120V AC. SVX2 motor, 12-gallon tank โ the highest-draw unit in this set. Field note: The SVX2 draws the most power in this set at 11.6A. Its estimated 4176W startup surge puts it beyond most mid-range power stations. If you need a shop vac specifically for portable power use, the 10A DeWalt is a safer choice. The SVX2 is best paired with stations rated 2500W+ continuous with 5000W surge. Why does the Shop-Vac draw more than the 6 HP Vacmaster? Peak HP is a marketing metric, not an electrical measurement. The SVX2 at 11.6A draws more real power than the 6 HP Beast at 11A. Always check nameplate amps, not HP ratings, for power station sizing. | |||||
This unit ranks #6 of 12 compatible generators for this device by buffered margin (Overkill class).
12 of 33 generators are SAFE+TIGHT for Shop Vac (Wet/Dry, 5-6 HP Peak).
Fit class uses buffered needs (running and surge) for this device.
Workshop Cleanup
Select Your Model:
Free Tools
The 7000W surge rating handles demanding startup loads including well pumps, air compressors, and window AC units. The dual 1200W MPPT controllers accept high-voltage panel strings (up to 150V), enabling efficient solar recharging in 1.5โ2 hours with 2400W of panels. At 3072Wh base capacity, expect 8+ hours of runtime on moderate loads. The expansion to 15kWh rivals whole-home battery systems.
The E3600LFP uses LiFePO4 chemistry rated for 3,500+ cycles to 80% capacity. The 51.2V battery architecture and UPS function (8โ20ms switchover) make it suitable for sensitive electronics and home backup. The TT30-R RV outlet follows NEMA standards for safe 30A connections. Source: Pecron official US product page (manufacturer documentation).
Keep your Shop Vac (Wet/Dry, 5-6 HP Peak) running with solar โข MPPT: 32โ 150V โข Max: 2400W
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Yes. The Pecron E3600LFP provides 3600W running / 7000W surge. The Shop Vac (Wet/Dry, 5-6 HP Peak) needs 1601W / 4803W (including 15% buffer). That leaves 1999W of running headroom and 2197W of surge margin.
Approximately 1.5 hours, based on the Shop Vac (Wet/Dry, 5-6 HP Peak)'s 1392W draw and the Pecron E3600LFP's 3072Wh capacity (70% usable after real-world losses).
With 1165W allocated to the Shop Vac (Wet/Dry, 5-6 HP Peak), the Pecron E3600LFP still has ~323W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your Pecron E3600LFP, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Shop Vac (Wet/Dry, 5-6 HP Peak)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Shop-Vac SVX2 (1392W at 11.6A). Surge worst case = Shop-Vac SVX2 (4176W). Surge estimated using 3x motor-load multiplier policy (no OEM starting watts published for any shop vac in this class).
Pecron E3600LFP Official Product Page (US) โ full specifications
Similar-output alternatives you can compare side by side.