Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
This pairing clears the safety headroom. Required ~1075W running and 4169W surge; the Explorer 3000 Pro is rated 3000W / 6000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,075W required -> 3,000W available (1,925W headroom)
Startup peak with safety buffer applied.
4,169W required -> 6,000W available (1,831W headroom)
Alternative startup path with reduced inrush.
1,876W required -> 6,000W available (4,124W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 2.5h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea EasyDry MDP70SR71 (70 Pint) | 690W | 3,335W | Safe | ~3.1h | OEM Manual |
Show expert analysisTechnical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โฅ3335W and continuous output โฅ690W are candidates. Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably. Can I run this dehumidifier on a portable power station overnight? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size. | |||||
| Midea EasyDry MDP70PR71 with Pump (70 Pint) | 690W | 3,335W | Safe | ~3.1h | OEM Manual |
Show expert analysisTechnical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection. Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw. Can I run this dehumidifier on a portable power station? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement. | |||||
| Haier HEN70ETF (70 Pint) | 860W | 2,580W | Safe | ~2.5h | OEM Verified |
Show expert analysisTechnical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping. Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw. Can I run this dehumidifier overnight on a portable power station? Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control. | |||||
This unit ranks #10 of 17 compatible generators for this device by buffered margin (Overkill class).
17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).
Fit class uses buffered needs (running and surge) for this device.
Basement Moisture Control
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
The 6000-watt surge capacity can handle typical compressor startup loads found in central AC units, well pumps, and refrigeration equipment. The 3000-watt continuous rating can support multiple simultaneous circuits during outages. This power profile suits households requiring reliable backup for motor-driven and resistive loads without relying on fuel-based generators.
This unit uses NMC chemistry and provides 3024 watt-hours of stored energy. Source: Market Data (January 2026), not OEM-listed (listed source reference). Consumers should follow all manufacturer operating instructions and confirm compatibility with their specific appliances before deployment.
Keep your Dehumidifier (70 Pint) running with solar โข MPPT: 17.5โ 60V โข Max: 1400W
Official 200W Panel
Smart Value 400W Panel
Adapter required: MC4 -> DC8020.
Smart Value 350W Panel
Adapter required: MC4 -> DC8020.
Yes. The Jackery Explorer 3000 Pro provides 3000W running / 6000W surge. The Dehumidifier (70 Pint) needs 1075W / 4169W (including 25% buffer). That leaves 1925W of running headroom and 1831W of surge margin.
Approximately 2.5 hours, based on the Dehumidifier (70 Pint)'s 860W draw and the Explorer 3000 Pro's 3024Wh capacity (70% usable after real-world losses).
With 1210W allocated to the Dehumidifier (70 Pint), the Explorer 3000 Pro still has ~330W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your Explorer 3000 Pro, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Dehumidifier (70 Pint)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).
Jackery Explorer 3000 Pro User Manual