Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
This pairing clears the safety headroom. Required ~200W running and 400W surge; the Explorer 1000 v2 is rated 1500W / 3000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
200W required -> 1,500W available (1,300W headroom)
Startup peak with safety buffer applied.
400W required -> 3,000W available (2,600W headroom)
Alternative startup path with reduced inrush.
180W required -> 3,000W available (2,820W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 4.7h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Frigidaire FFFU16F2VW (16 Cu. Ft. Upright, Auto-Defrost) (320W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| GE FUF17DLRWW (17.3 Cu. Ft. Upright, Frost-Free, Garage Ready) | 153W | 306W | Safe | ~4.9h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 153W estimated from 441 kWh/yr at 0.33 duty cycle. **Estimated startup surge:** 306W at 2.0x running (conservative โ no OEM LRA published). **Voltage:** 120V AC. Frost-free upright with electronic temperature control and garage-ready certification (0ยฐF to 110ยฐF ambient). Field note: Garage-ready certification means this freezer has an internal heater that activates in cold ambient conditions to keep the compressor warm. In winter garage use on battery power, energy consumption may increase โ counter-intuitive but important for sizing. The 20A on the spec sheet is the circuit breaker requirement, not the actual draw. Can a portable power station keep this GE upright freezer running during an outage? At 153W running with 306W estimated surge, most power stations above 500W continuous can handle this freezer. A 1,000 Wh battery provides roughly 14 hours of runtime at average draw. | |||||
| Frigidaire FFFU16F2VW (16 Cu. Ft. Upright, Auto-Defrost) | 160W | 320W | Safe | ~4.7h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 160W estimated from 461 kWh/yr at 0.33 duty cycle. **Estimated startup surge:** 320W at 2.0x running (conservative โ no OEM LRA published). **Voltage:** 120V AC. Auto-defrost upright with wire shelving and R-600A refrigerant. Field note: The Frigidaire is the most affordable option but also the least efficient at 461 kWh/yr. For extended outage use on battery power, the extra ~55 Wh/day versus the GE upright adds up over multi-day events. Not garage-rated โ performance may degrade in unheated spaces below 55ยฐF. How long can a portable power station run this Frigidaire freezer? At 160W running with 320W estimated surge, a 1,000 Wh power station provides roughly 13 hours at average draw. For a full 24-hour outage, budget at least 1,300 Wh of usable station capacity. | |||||
| GE FCM16DLWW (15.7 Cu. Ft. Chest, Manual Defrost, Garage Ready) | 127W | 254W | Safe | ~5.9h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 127W estimated from 277 kWh/yr at 0.25 duty cycle. **Estimated startup surge:** 254W at 2.0x running (conservative โ no OEM LRA published). **Voltage:** 120V AC. Manual-defrost chest freezer with top-opening lid and garage-ready certification (0ยฐF to 110ยฐF ambient). Field note: This is the most power-station-friendly freezer in the set. Manual defrost means no surprise heater cycles draining the battery. The chest design retains cold for 36-48 hours without power if kept closed โ buying critical time during extended outages. Garage-ready certification adds a compressor heater for cold ambient, but in summer outage scenarios it stays dormant. Why is the chest freezer so much more efficient on battery power? Three reasons: top-opening lid prevents cold air from falling out when opened, thicker insulation reduces heat gain, and manual defrost eliminates the periodic 400-600W heater cycle that upright auto-defrost models run every 12-24 hours. | |||||
This unit ranks #13 of 32 compatible generators for this device by buffered margin (Overkill class).
32 of 33 generators are SAFE+TIGHT for Full-Size Freezer (15-17 Cu. Ft.).
Fit class uses buffered needs (running and surge) for this device.
Extended Food Storage
Select Your Model:
Free Tools
This unit can handle typical compressor-based loads like refrigerators and window AC units where startup surge falls within the 3000W envelope. The 1070Wh capacity supports moderate runtime on continuous loads under 1500W. It can start most residential sump pumps and small well pumps where inrush demand does not exceed the rated surge threshold.
LFP chemistry provides a stable platform for managing high-current transients during motor startup events. The 3000W surge rating allows the unit to absorb brief inrush currents without shutdown, though users must verify compatibility with specific appliances. Source: Jackery Explorer 1000 v2 User Manual (Sept 2024) (manufacturer documentation).
Keep your Full-Size Freezer (15-17 Cu. Ft.) running with solar โข MPPT: 16โ 60V โข Max: 400W
Official 200W Panel
Smart Value 200W Panel
Adapter required: MC4 -> DC8020.
Smart Value 200W Panel
Adapter required: MC4 -> DC8020.
Yes. The Jackery Explorer 1000 v2 provides 1500W running / 3000W surge. The Full-Size Freezer (15-17 Cu. Ft.) needs 200W / 400W (including 25% buffer). That leaves 1300W of running headroom and 2600W of surge margin.
Approximately 4.7 hours, based on the Full-Size Freezer (15-17 Cu. Ft.)'s 160W draw and the Explorer 1000 v2's 1070Wh capacity (70% usable after real-world losses).
With 970W allocated to the Full-Size Freezer (15-17 Cu. Ft.), the Explorer 1000 v2 still has ~70W of margin. These devices could run simultaneously:
Storm Safety: Since the Full-Size Freezer (15-17 Cu. Ft.) is critical for preventing flooding, we recommend testing this setup specifically before the storm season. Ensure the Explorer 1000 v2 is fully charged to 100% as storms approach.
Compare all 33 generators for the Full-Size Freezer (15-17 Cu. Ft.)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Worst case = Frigidaire FFFU16F2VW (160W running, 320W surge). Running watts derived from OEM kWh/yr via duty-cycle formula; surge estimated at 2.0x (conservative, no OEM LRA published for any freezer in this class).
Jackery Explorer 1000 v2 User Manual (Sept 2024)