Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
2 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,100W to 1,981W required -> 1,500W available (400W headroom on lighter models)
Startup peak with safety buffer applied.
1,100W to 1,981W required -> 3,000W available (1,019W to 1,900W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.4h
Device profile reference: up to 1h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
2 of 3 models are SAFE or TIGHT. Most demanding model: Duxtop Portable Induction Cooktop (1800W) (1,800W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Duxtop Portable Induction Cooktop (1800W) | 1,800W | 1,800W | Fail | โ | OEM Manual |
Show expert analysisTechnical: **Running load:** 1800 W. **Surge:** 1800 W (resistive heating element, no inrush spike). **Voltage:** 120 V AC required. Power station must sustain 1800 W continuous output on AC inverter. Field note: Verify power station inverter rating is at least 2000 W continuous to allow headroom. Resistive load provides stable draw without cyclic spikes. Can I run this induction cooktop on a 1500 W power station? Only if your power source can supply at least 1800W continuous and 1800W surge at 120V. | |||||
| Cuisinart CB-30 Cast-Iron Single Burner | 1,300W | 1,300W | Safe | ~0.6h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1300 W at 120V. **Surge:** 1300 W (resistive heating element, no motor startup). Requires power station with continuous 1300 W rating and 120V AC outlet. Field note: Verify power station continuous output meets or exceeds 1300 W. Insufficient headroom will trigger overload shutdown during cooking. Can I use this burner with a 1000W power station? Only if your power source can supply at least 1300W continuous and 1300W surge at 120V. | |||||
| Ovente BGC101S Single Electric Burner | 1,000W | 1,000W | Safe | ~0.7h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1000 W. **Surge:** 1000 W. **Voltage:** 120 V AC. Resistive heating element draws steady current with no inrush spike. Power station must supply clean 120 V output and sustain 1000 W continuous. Field note: Verify power station AC outlet delivers rated continuous output. Undersized inverters will overheat or shut down under sustained resistive load. Can I use this burner with a 500 Wh portable power station? Only if your power source can supply at least 1000W continuous and 1000W surge at 120V. Runtime would be approximately 30 minutes before depletion, provided inverter does not thermally limit first. | |||||
This unit is outside the compatible set; 21 of 33 generators pass SAFE/TIGHT for this device.
21 of 33 generators are SAFE+TIGHT for Electric Stove (Single Burner).
Fit class uses buffered needs (running and surge) for this device.
Portable Cooking
Select Your Model:
This load may exceed a standard 15A outlet. Verify your station has a higher-amperage outlet (20A/30A) before purchase.
Free Tools
This unit can handle typical compressor-based loads like refrigerators and window AC units where startup surge falls within the 3000W envelope. The 1070Wh capacity supports moderate runtime on continuous loads under 1500W. It can start most residential sump pumps and small well pumps where inrush demand does not exceed the rated surge threshold.
LFP chemistry provides a stable platform for managing high-current transients during motor startup events. The 3000W surge rating allows the unit to absorb brief inrush currents without shutdown, though users must verify compatibility with specific appliances. Source: Jackery Explorer 1000 v2 User Manual (Sept 2024) (manufacturer documentation).
Keep your Electric Stove (Single Burner) running with solar โข MPPT: 16โ 60V โข Max: 400W
Official 200W Panel
Smart Value 200W Panel
Adapter required: MC4 -> DC8020.
Smart Value 200W Panel
Adapter required: MC4 -> DC8020.
It depends on the model. 2 of 3 Electric Stove (Single Burner) models are compatible with the Jackery Explorer 1000 v2. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 0.6โ0.7 hours on the Explorer 1000 v2. 1 of 3 models are not compatible. See the model-specific results for details.
Efficiency Hack: Large appliances like the Electric Stove (Single Burner) cycle on and off. To maximize the 0.4 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the Electric Stove (Single Burner)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Duxtop Portable Induction Cooktop 1800W (1800W). Surge = running (resistive heating element โ no motor inrush).
Jackery Explorer 1000 v2 User Manual (Sept 2024)
Similar-output alternatives you can compare side by side.