Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
1 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
173W to 403W required -> 300W available (127W headroom on lighter models)
Startup peak with safety buffer applied.
173W to 403W required -> 600W available (197W to 427W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.5h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
1 of 3 models are SAFE or TIGHT. Most demanding model: Philips EverFlo (350W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Philips SimplyGo | 150W | 150W | Safe | ~1.2h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 150 W. **Surge:** 150 W. **Voltage:** 120 V AC. No inrush spike, consistent draw across flow settings. Field note: Verify power station inverter can deliver 150 W continuously for 24-hour cycles. Monitor battery state of charge during overnight operation. Can I run this concentrator on battery backup during a power outage? Only if your power source can supply at least 150W continuous and 150W surge at 120V. | |||||
| Philips EverFlo | 350W | 350W | Fail | โ | OEM Verified |
Show expert analysisTechnical: **Running load:** 350W continuous. **Surge:** 350W (no inrush spike). **Voltage requirement:** 120V AC. Resistive heating element drives steady draw with minimal transient. Field note: Ensure power station inverter handles 350W continuous without thermal cutoff. Voltage deviation beyond ยฑ5% may trigger device fault alarms. Can I run this on a portable power station during an outage? Only if your power source can supply at least 350W continuous and 350W surge at 120V. Verify capacity in watt-hours exceeds your runtime need. | |||||
| Drive DeVilbiss 5L | 310W | 310W | Fail | โ | Engineering Est. |
Show expert analysisTechnical: **Running load:** 310W continuous. **Surge:** 310W (no starting transient). **Voltage:** requires 120V AC. The device demands 7440 Wh over a 24-hour period. Field note: Medical oxygen concentrators tolerate no interruption. Verify the power station supports pass-through charging during mains operation. Can I run this oxygen concentrator on a portable power station during an outage? Only if your power source can supply at least 310W continuous and 310W surge at 120V. No compatibility is guaranteed. | |||||
This unit is outside the compatible set; 29 of 33 generators pass SAFE/TIGHT for this device.
29 of 33 generators are SAFE+TIGHT for Portable Oxygen Concentrator.
Fit class uses buffered needs (running and surge) for this device.
Medical Emergency Backup
Select Your Model:
Free Tools
The 600 W surge window can support typical compressor-based startup loads found in small refrigerators, window AC units, and sump pumps. The 256 Wh capacity limits sustained runtime, but the 2:1 surge-to-running ratio can handle brief inrush currents during motor startup events. This unit can manage intermittent high-demand appliances in portable or backup scenarios.
LFP chemistry provides stable operation across discharge cycles. The 300 W continuous rating with 600 W surge headroom allows brief high-draw events without immediate overload shutdown. Source: EcoFlow RIVER 2 User Manual v1.0 (OEM documentation).
Keep your Portable Oxygen Concentrator running with solar โข MPPT: 11โ 30V โข Max: 110W
Official 110W Panel
Adapter required: MC4 -> XT60.
Smart Value 100W Panel
Adapter required: Goal Zero proprietary -> XT60 adapter required.
Smart Value 100W Panel
Adapter required: Jackery proprietary -> XT60 adapter required.
It depends on the model. 1 of 3 Portable Oxygen Concentrator models are compatible with the EcoFlow RIVER 2. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 1.2โ1.2 hours on the RIVER 2. 2 of 3 models are not compatible. See the model-specific results for details.
Pro Tip for Medical Users: According to energy reports, turning off the humidifier on your Portable Oxygen Concentrator can double your runtime. Using a DC cable instead of the AC plug is also recommended to avoid inverter inefficiency.
Compare all 33 generators for the Portable Oxygen Concentrator
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Philips EverFlo (350W). Surge = running for all variants (no OEM startup current published for any oxygen concentrator in this class; surge modeled equal to running).
EcoFlow RIVER 2 User Manual v1.0
Similar-output alternatives you can compare side by side.