Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
Yes - RIVER 2 has enough running and surge power for the Electric Blanket. Target ~199W running / 199W surge; the generator provides 300W / 600W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
199W required -> 300W available (101W headroom)
Startup peak with safety buffer applied.
199W required -> 600W available (401W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 1.0h
Device profile reference: up to 8h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
5 of 5 models are SAFE or TIGHT. Most demanding model: Biddeford Electric Warming Blanket (Full) (180W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Biddeford Electric Warming Blanket (Full) | 180W | 180W | Safe | ~1.0h | OEM Verified |
Show expert analysisTechnical: **Running load:** 180 W. **Surge:** 180 W (resistive heating element, no inrush). **Voltage:** 120 V AC. A power station with at least 200 W continuous AC output and 120 V support is the minimum threshold. Field note: Verify the power station AC outlet provides 120 V. Resistive loads tolerate most inverter waveforms, but confirm the station's continuous rating exceeds 180 W. Can I run this blanket overnight on battery power? Only if your power source can supply at least 180W continuous and 180W surge at 120V. It depends on the power station's usable capacity. An 8-hour session requires at least 1440 Wh, so only stations rated above that threshold (accounting for inverter losses) will complete the full cycle. | |||||
| Westinghouse Heated Throw (50x60) | 100W | 100W | Safe | ~1.8h | OEM Verified |
Show expert analysisTechnical: **Running load:** 100W. **Surge:** 100W (resistive heating element). Requires 120V AC output from the power station. No surge spike present, as heating coils draw constant current. Field note: Verify your power station's inverter can sustain 100W for the full duration. Cold ambient temperatures may reduce battery capacity by 10-20%. Can I run this heated throw all night on a 500Wh power station? Only if your power source can supply at least 100W continuous and 100W surge at 120V. Only if you limit use to roughly 4-5 hours, accounting for inverter losses and reduced cold-weather battery performance. | |||||
| Sunbeam Microplush Ultimate Grey Heated Blanket (Queen) | 110W | 110W | Safe | ~1.6h | OEM Verified |
Show expert analysisTechnical: **Running load:** 110 W. **Surge:** 110 W (resistive heating, no inrush). **Voltage:** 120 V AC required. Draws constant wattage during active heating cycles. Field note: Verify power station AC outlet delivers stable 120 V under continuous 110 W load. Low wattage allows extended runtime on modest battery capacities. Can I run this heated blanket overnight on a portable power station? Only if your power source can supply at least 110W continuous and 110W surge at 120V. It depends on the power station's usable capacity and AC output rating. | |||||
| Sunbeam Brushed Fleece Heated Throw (Greystone) | 110W | 110W | Safe | ~1.6h | OEM Verified |
Show expert analysisTechnical: **Running load:** 110W. **Surge:** 110W. Requires 120V AC. Resistive heating element draws steady current with no inrush spike. Field note: Verify power station maintains 120V output under resistive load. Allow 15% inverter headroom for thermal stability. Can I run this heated throw all night on a portable power station? Only if your power source can supply at least 110W continuous and 110W surge at 120V. | |||||
| Sunbeam 2-in-1 Reversible Heated & Cooling Mattress Pad (Queen) | 110W | 110W | Safe | ~1.6h | OEM Verified |
Show expert analysisTechnical: **Running load:** 110 W continuous. **Surge:** 110 W (resistive heating element, no inrush). **Voltage:** 120 V AC required. Power station must supply stable 120 V AC output and deliver at least 110 W continuously for the duration of use. Field note: Verify power station capacity exceeds 880 Wh if running the full night. Thermal mattress pads draw steady power until thermostat cycles. Can I run this mattress pad through the night on a portable power station? Only if your power source can supply at least 110W continuous and 110W surge at 120V. Runtime depends on actual capacity and inverter efficiency. | |||||
This unit ranks #2 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for Electric Blanket.
Fit class uses buffered needs (running and surge) for this device.
Cold Night Warmth
Select Your Model:
Free Tools
The 600 W surge window can support typical compressor-based startup loads found in small refrigerators, window AC units, and sump pumps. The 256 Wh capacity limits sustained runtime, but the 2:1 surge-to-running ratio can handle brief inrush currents during motor startup events. This unit can manage intermittent high-demand appliances in portable or backup scenarios.
LFP chemistry provides stable operation across discharge cycles. The 300 W continuous rating with 600 W surge headroom allows brief high-draw events without immediate overload shutdown. Source: EcoFlow RIVER 2 User Manual v1.0 (OEM documentation).
Keep your Electric Blanket running with solar โข MPPT: 11โ 30V โข Max: 110W
Official 110W Panel
Adapter required: MC4 -> XT60.
Smart Value 100W Panel
Adapter required: Goal Zero proprietary -> XT60 adapter required.
Smart Value 100W Panel
Adapter required: Jackery proprietary -> XT60 adapter required.
Yes. The EcoFlow RIVER 2 provides 300W running / 600W surge. The Electric Blanket needs 199W / 199W (including 10% buffer). That leaves 101W of running headroom and 401W of surge margin.
Approximately 1.0 hours, based on the Electric Blanket's 180W draw and the RIVER 2's 256Wh capacity (70% usable after real-world losses).
With 45W allocated to the Electric Blanket, the RIVER 2 still has ~15W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your RIVER 2, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Electric Blanket
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Biddeford Electric Warming Blanket (Full) (180W). Surge = running (resistive heating element โ no motor inrush).
EcoFlow RIVER 2 User Manual v1.0