Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
No - this pairing is underpowered. Safe target ~1297W running / 3889W surge; the generator provides 800W / 1600W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,297W required -> 800W available (497W short)
Startup peak with safety buffer applied.
3,889W required -> 1,600W available (2,289W short)
Alternative startup path with reduced inrush.
1,750W required -> 1,600W available (150W short)
Runtime context only. It does not change the electrical compatibility verdict.
Runtime estimate appears after running and surge gates pass.
Power bars show required versus available output for each gate.
See generators that pass nativelyQuick compatibility, required headroom, and model-specific context at a glance.
0 of 3 models are SAFE or TIGHT. Most demanding model: Wayne CDU800 (1/2 HP) (3,381W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Zoeller M98 Flow-Mate (1/2 HP) | 1,081W | 3,243W | Fail | โ | NEC Standard |
Show expert analysisTechnical: **Running load:** 1,081W (115V x 9.4A OEM rated). **Surge:** 3,243W at motor startup (3x NEC estimate). **Voltage:** 120V AC. The cast iron PSC motor draws heavy inrush current on every pump cycle. Field note: The Zoeller M98 is the industry reference in cast iron sump pumps. Its PSC motor has no built-in soft-start โ the full inrush hits the power station instantly. An external soft-start device can reduce this surge, but size the inverter for the full 3,243W if running without one. Can I run a Zoeller M98 sump pump on a portable power station during a flood? Only if your power source can supply at least 1,081W continuous and 3,243W surge at 120V. The PSC motor creates a hard startup spike that will trip undersized inverters. | |||||
| Wayne CDU800 (1/2 HP) | 1,127W | 3,381W | Fail | โ | NEC Standard |
Show expert analysisTechnical: **Running load:** 1,127W (NEC 430.248 rated). **Surge:** 3,381W at motor startup (3x NEC estimate). **Voltage:** 120V AC. The coated steel PSC motor draws the highest inrush in this class due to its conservative NEC-rated amperage. Field note: The Wayne CDU800 is the Home Depot best-seller for suburban basements. Without OEM amperage data, specs are derived from NEC tables โ the actual draw may be slightly lower, but sizing to NEC ensures safe headroom. Can I keep my Wayne sump pump running on battery backup during a storm? Only if your power source can supply at least 1,127W continuous and 3,381W surge at 120V. The motor startup surge is the critical factor โ most small power stations cannot handle it. | |||||
| Liberty Pumps 287 VMF (1/2 HP) | 920W | 2,645W | Fail | โ | OEM Manual |
Show expert analysisTechnical: **Running load:** 920W (115V x 8.0A OEM rated). **Surge:** 2,645W at motor startup (115V x 23A LRA, OEM verified). **Voltage:** 120V AC. The 3450 RPM PSC motor with OEM-documented LRA provides the most precise surge data in this class. Field note: The Liberty 287 is the plumber's choice and the most battery-friendly 1/2 HP sump pump in this comparison. With OEM-verified LRA data, the 2,645W surge is a confirmed number โ not an estimate. A 3,000W power station can handle this reliably. Is the Liberty 287 easier to run on a power station than other sump pumps? Only if your power source can supply at least 920W continuous and 2,645W surge at 120V. Its OEM-documented 23A locked rotor current is lower than NEC estimates for competing 1/2 HP pumps, making it more generator-friendly. | |||||
This unit is outside the compatible set; 17 of 33 generators pass SAFE/TIGHT for this device.
17 of 33 generators are SAFE+TIGHT for Sump Pump (1/2 HP).
Fit class uses buffered needs (running and surge) for this device.
Storm Flood Prevention
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
These generators meet Sump Pump (1/2 HP)'s voltage, running, and surge requirements.
3000W โข 2042Wh
Lowest capacity that still clears surge + running load.
3600W โข 3600Wh
Expandable to 25000Wh.
Free Tools
The 1600W surge rating can handle typical motor startup events found in residential compressor-based appliances like refrigerators and well pumps. The 800W running capacity can support continuous loads such as home network equipment, lighting circuits, and small kitchen appliances. This configuration works well for targeted backup scenarios rather than whole-home replacement power.
This unit uses LFP chemistry, which offers stable thermal characteristics during discharge cycles. The 768Wh capacity supports extended runtime for moderate household loads. Source: EcoFlow RIVER 2 Pro User Manual v1.0 (manufacturer documentation).
No. The EcoFlow RIVER 2 Pro falls short on both running (800W offered vs 1297W needed) and surge (1600W offered vs 3889W needed). Safe targets include a 15% buffer for the Sump Pump (1/2 HP)'s motor load profile.
No reliable runtime estimate โ this pairing is not compatible. The EcoFlow RIVER 2 Pro cannot safely power the Sump Pump (1/2 HP). See compatible alternatives above for power stations that meet this device's requirements.
Storm Safety: Since the Sump Pump (1/2 HP) is critical for preventing flooding, we recommend testing this setup specifically before the storm season. Ensure the RIVER 2 Pro is fully charged to 100% as storms approach.
Compare all 33 generators for the Sump Pump (1/2 HP)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Worst case = Wayne CDU800 (1127W running, 3381W surge).
EcoFlow RIVER 2 Pro User Manual v1.0
Similar-output alternatives you can compare side by side.