Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
This pairing clears the safety headroom. Required ~330W running and 330W surge; the Delta Pro is rated 3600W / 7200W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
330W required -> 3,600W available (3,270W headroom)
Startup peak with safety buffer applied.
330W required -> 7,200W available (6,870W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 8.4h
Device profile reference: up to 6h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Crock-Pot 7-Quart Manual Slow Cooker (SAP_2131381) (300W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Crock-Pot 6-Quart Cook and Carry (SCCPVL610SA) | 240W | 240W | Safe | ~10.5h | OEM Verified |
Show expert analysisTechnical: **Running load:** 240 W. **Surge:** 240 W (no inrush spike). **Voltage:** 120 V AC required. Resistive heating element draws steady current with no motor or compressor startup transient. Field note: Verify power station AC inverter capacity exceeds 240 W continuous rating. Reserve at least 20% headroom (300 W minimum inverter rating) for thermal stability during extended runtime. Can I run this slow cooker on a portable power station all day? Only if your power source can supply at least 240W continuous and 240W surge at 120V. | |||||
| Crock-Pot 7-Quart Manual Slow Cooker (SAP_2131381) | 300W | 300W | Safe | ~8.4h | OEM Verified |
Show expert analysisTechnical: **Running load:** 300 W. **Surge:** 300 W (resistive heating element, no motor startup). **Voltage:** 120 V AC required. Power station must sustain 300 W continuous output at 120 V for safe operation. Field note: Verify power station rated capacity exceeds 1800 Wh if running the full daily cycle. Add 10-15% margin for inverter efficiency losses. Can I cook an 8-hour recipe on a single charge? Only if your power source can supply at least 300W continuous and 300W surge at 120V. It depends on the power station's usable capacity. An 8-hour cook cycle requires 2400 Wh minimum, plus inverter overhead. Verify your unit's rated watt-hours before planning extended recipes. | |||||
| Crock-Pot 4.5-Quart Manual Slow Cooker (SAP_2131365) | 210W | 210W | Safe | ~12.0h | OEM Verified |
Show expert analysisTechnical: **Running load:** 210 W. **Surge:** 210 W (resistive heating element, no inrush). **Voltage:** 120 V AC required. Power station must deliver clean 120 V output and at least 210 W continuous capacity. Field note: Verify power station capacity exceeds 1260 Wh if running a full daily cook cycle on battery alone. Leave 15 percent headroom for inverter efficiency loss. Can I run this slow cooker for 8 hours on a 1500 Wh power station? Only if your power source can supply at least 210W continuous and 210W surge at 120V. | |||||
This unit ranks #28 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for Slow Cooker.
Fit class uses buffered needs (running and surge) for this device.
All-Day Slow Cooking
Select Your Model:
Free Tools
The 7200W surge capacity can support typical motor-driven appliances during startup, including air compressor motors, well pumps, and refrigeration units that demand brief high-current events. The 3600Wh capacity provides extended runtime for moderate loads, though actual performance depends on connected equipment and environmental conditions. This unit can handle typical whole-home essentials when loads are properly managed.
The Delta Pro uses LFP chemistry, a lithium iron phosphate formulation widely recognized for thermal stability in residential applications. The manufacturer provides operational guidance in their documentation, but users must follow all installation and usage instructions to minimize risk. Source: EcoFlow DELTA Pro User Manual v1.1 (manufacturer documentation).
Keep your Slow Cooker running with solar โข MPPT: 11โ 150V โข Max: 1600W
Official 400W Panel
Adapter required: MC4 -> XT60i.
Smart Value 400W Panel
Adapter required: MC4 -> XT60i.
Smart Value 350W Panel
Adapter required: MC4 -> XT60i.
Yes. The EcoFlow Delta Pro provides 3600W running / 7200W surge. The Slow Cooker needs 330W / 330W (including 10% buffer). That leaves 3270W of running headroom and 6870W of surge margin.
Approximately 8.4 hours, based on the Slow Cooker's 300W draw and the Delta Pro's 3600Wh capacity (70% usable after real-world losses).
With 2570W allocated to the Slow Cooker, the Delta Pro still has ~10W of margin. These devices could run simultaneously:
Efficiency Hack: Large appliances like the Slow Cooker cycle on and off. To maximize the 8.4 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the Slow Cooker
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Crock-Pot 7-Quart Manual Slow Cooker (SAP_2131381) (300W). Surge = running (resistive heating element โ no motor inrush).
EcoFlow DELTA Pro User Manual v1.1
Similar-output alternatives you can compare side by side.