Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
Yes - Delta Pro has enough running and surge power for the Electric Stove (Single Burner). Target ~1981W running / 1981W surge; the generator provides 3600W / 7200W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,981W required -> 3,600W available (1,619W headroom)
Startup peak with safety buffer applied.
1,981W required -> 7,200W available (5,219W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 1.4h
Device profile reference: up to 1h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Duxtop Portable Induction Cooktop (1800W) (1,800W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Duxtop Portable Induction Cooktop (1800W) | 1,800W | 1,800W | Safe | ~1.4h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1800 W. **Surge:** 1800 W (resistive heating element, no inrush spike). **Voltage:** 120 V AC required. Power station must sustain 1800 W continuous output on AC inverter. Field note: Verify power station inverter rating is at least 2000 W continuous to allow headroom. Resistive load provides stable draw without cyclic spikes. Can I run this induction cooktop on a 1500 W power station? Only if your power source can supply at least 1800W continuous and 1800W surge at 120V. | |||||
| Cuisinart CB-30 Cast-Iron Single Burner | 1,300W | 1,300W | Safe | ~1.9h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1300 W at 120V. **Surge:** 1300 W (resistive heating element, no motor startup). Requires power station with continuous 1300 W rating and 120V AC outlet. Field note: Verify power station continuous output meets or exceeds 1300 W. Insufficient headroom will trigger overload shutdown during cooking. Can I use this burner with a 1000W power station? Only if your power source can supply at least 1300W continuous and 1300W surge at 120V. | |||||
| Ovente BGC101S Single Electric Burner | 1,000W | 1,000W | Safe | ~2.5h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1000 W. **Surge:** 1000 W. **Voltage:** 120 V AC. Resistive heating element draws steady current with no inrush spike. Power station must supply clean 120 V output and sustain 1000 W continuous. Field note: Verify power station AC outlet delivers rated continuous output. Undersized inverters will overheat or shut down under sustained resistive load. Can I use this burner with a 500 Wh portable power station? Only if your power source can supply at least 1000W continuous and 1000W surge at 120V. Runtime would be approximately 30 minutes before depletion, provided inverter does not thermally limit first. | |||||
This unit ranks #16 of 21 compatible generators for this device by buffered margin (Overkill class).
21 of 33 generators are SAFE+TIGHT for Electric Stove (Single Burner).
Fit class uses buffered needs (running and surge) for this device.
Portable Cooking
Select Your Model:
This load may exceed a standard 15A outlet. Verify your station has a higher-amperage outlet (20A/30A) before purchase.
Free Tools
The 7200W surge capacity can support typical motor-driven appliances during startup, including air compressor motors, well pumps, and refrigeration units that demand brief high-current events. The 3600Wh capacity provides extended runtime for moderate loads, though actual performance depends on connected equipment and environmental conditions. This unit can handle typical whole-home essentials when loads are properly managed.
The Delta Pro uses LFP chemistry, a lithium iron phosphate formulation widely recognized for thermal stability in residential applications. The manufacturer provides operational guidance in their documentation, but users must follow all installation and usage instructions to minimize risk. Source: EcoFlow DELTA Pro User Manual v1.1 (manufacturer documentation).
Keep your Electric Stove (Single Burner) running with solar โข MPPT: 11โ 150V โข Max: 1600W
Official 400W Panel
Adapter required: MC4 -> XT60i.
Smart Value 400W Panel
Adapter required: MC4 -> XT60i.
Smart Value 350W Panel
Adapter required: MC4 -> XT60i.
Yes. The EcoFlow Delta Pro provides 3600W running / 7200W surge. The Electric Stove (Single Burner) needs 1981W / 1981W (including 10% buffer). That leaves 1619W of running headroom and 5219W of surge margin.
Approximately 1.4 hours, based on the Electric Stove (Single Burner)'s 1800W draw and the Delta Pro's 3600Wh capacity (70% usable after real-world losses).
With 1075W allocated to the Electric Stove (Single Burner), the Delta Pro still has ~5W of margin. These devices could run simultaneously:
Efficiency Hack: Large appliances like the Electric Stove (Single Burner) cycle on and off. To maximize the 1.4 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the Electric Stove (Single Burner)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Duxtop Portable Induction Cooktop 1800W (1800W). Surge = running (resistive heating element โ no motor inrush).
EcoFlow DELTA Pro User Manual v1.1
Similar-output alternatives you can compare side by side.