Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
Yes - Delta Pro Ultra X has enough running and surge power for the CPAP Machine. Target ~65W running / 120W surge; the generator provides 12000W / 24000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
65W required -> 12,000W available (11,935W headroom)
Startup peak with safety buffer applied.
120W required -> 24,000W available (23,880W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 76.7h
Device profile reference: up to 8h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: ResMed AirSense 10 AutoSet (104W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| ResMed AirSense 11 AutoSet | 56.1W | 73.2W | Safe | ~76.7h | OEM Manual |
Show expert analysisTechnical: **Running load:** 56.1 W typical. **Surge:** 73.2 W peak. **Voltage:** 120 V AC. The machine draws continuous low power with minimal startup spike. Most portable power stations with 120V inverters and 100+ W output handle this load comfortably. Field note: Verify your power station provides stable 120V AC output and at least 75W continuous rating. Disable the heated humidifier to reduce draw by ~30% and extend runtime. Always carry a backup power source for life-critical equipment. Can I run the AirSense 11 on a 500Wh power station? Yes โ at 56.1W typical, a 500Wh station (350Wh usable) provides roughly 6 hours. Disabling the humidifier drops draw to ~40W and extends runtime to a full night. | |||||
| ResMed AirSense 10 AutoSet | 53W | 104W | Safe | ~81.1h | OEM Manual |
Show expert analysisTechnical: **Running load:** 53 W typical. **Surge:** 104 W peak. **Voltage:** 120 V AC required. The AirSense 10 has a higher peak draw than the newer AirSense 11 due to its older motor design. Field note: The 104W peak is the sizing constraint. Ensure your power station can handle at least 120W continuous to cover the startup surge with margin. Use a pure sine wave inverter โ modified sine wave may cause motor faults in medical devices. Can I use a portable power station rated for 100W continuous? Risky โ the AirSense 10 peaks at 104W. A station rated at exactly 100W may trip on startup. Look for 150W+ continuous rating to be safe. | |||||
| Fisher & Paykel SleepStyle Auto | 39W | 76W | Safe | ~110.3h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 39 W typical. **Surge:** 76 W peak. **Voltage:** 120 V AC required. The SleepStyle has an integrated power supply (no external brick) and built-in heated humidifier. The 39W figure includes the humidifier at typical settings. Field note: The SleepStyle is the most power-efficient full-size CPAP here. At 39W typical, even a compact 500Wh power station covers a full night with margin. The integrated humidifier means no separate heater to add to the load. Is the Fisher & Paykel SleepStyle easier to run off-grid than ResMed? Yes โ at 39W typical vs 53-56W for ResMed models, the SleepStyle draws roughly 30% less power. An 8-hour night consumes ~312 Wh vs 424-449 Wh for ResMed. | |||||
This unit ranks #33 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for CPAP Machine.
Fit class uses buffered needs (running and surge) for this device.
8-Hour Sleep Session
Select Your Model:
Free Tools
With 24,000W surge capacity, this system can handle typical compressor startup events found in central air conditioners, well pumps, and refrigeration equipment. The 12,000W continuous rating supports sustained high-load operation across multiple circuits. At 6,144Wh usable capacity, runtime depends on connected load, but this configuration can support whole-home essentials during extended outages.
This unit uses LFP chemistry, a formulation widely recognized for thermal stability in residential backup applications. The manufacturer provides operational guidelines in their documentation, and users should follow all installation and grounding instructions. Source: EcoFlow DELTA Pro Ultra X User Manual (manufacturer documentation).
Keep your CPAP Machine running with solar โข MPPT: 80โ 500V โข Max: 10000W
Official 400W Panel
Requires 2 panels in series to reach the 80V start threshold.
Smart Value 400W Panel
Requires 2 panels in series to reach the 80V start threshold.
Smart Value 350W Panel
Requires 3 panels in series to reach the 80V start threshold.
Yes. The EcoFlow Delta Pro Ultra X provides 12000W running / 24000W surge. The CPAP Machine needs 65W / 120W (including 15% buffer). That leaves 11935W of running headroom and 23880W of surge margin.
Approximately 76.7 hours, based on the CPAP Machine's 56W draw and the Delta Pro Ultra X's 6144Wh capacity (70% usable after real-world losses).
With 1960W allocated to the CPAP Machine, the Delta Pro Ultra X still has ~7584W of margin. These devices could run simultaneously:
Pro Tip for Medical Users: According to energy reports, turning off the humidifier on your CPAP Machine can double your runtime. Using a DC cable instead of the AC plug is also recommended to avoid inverter inefficiency.
Compare all 33 generators for the CPAP Machine
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = ResMed AirSense 11 (56.1W typical). Surge worst case = ResMed AirSense 10 (104W peak).
EcoFlow DELTA Pro Ultra X User Manual
Similar-output alternatives you can compare side by side.