Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
Yes - Delta Pro Ultra X has enough running and surge power for the Pancake Air Compressor (6-Gallon). Target ~2025W running / 10429W surge; the generator provides 12000W / 24000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
2,025W required -> 12,000W available (9,975W headroom)
Startup peak with safety buffer applied.
10,429W required -> 24,000W available (13,571W headroom)
Alternative startup path with reduced inrush.
4,693W required -> 24,000W available (19,307W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 2.7h
Device profile reference: up to 1h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Metabo HPT EC914S 'The Tank' (6-Gal, 1.3 HP, 200 PSI) (8,343W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| DeWalt DWFP55126 (6-Gal, 0.9 HP, 165 PSI) | 1,200W | 6,180W | Safe | ~3.6h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 1200W from OEM rated amps (10A ร 120V). **Estimated startup surge:** 6180W at 5.15x running (proxy from CRAFTSMAN OEM data for comparable 6-gallon pancake compressor โ no DeWalt starting watts published). **Voltage:** 120V AC. Oil-free pump, 0.9 HP universal motor, 165 PSI max. Field note: The DWFP55126 is the best-selling pancake compressor in the US. Despite the modest 1200W running draw, the ~6180W startup surge means most power stations under 3000W surge capacity will trip on compressor restart. Size for surge first, not running watts. Can a portable power station run the DeWalt DWFP55126? Only if your power source can supply at least 1200W continuous and approximately 6180W surge at 120V. The compressor startup surge is the main limiting factor, not the running watts. | |||||
| CRAFTSMAN CMEC6150 (6-Gal, 0.8 HP, 150 PSI) | 1,320W | 6,800W | Safe | ~3.3h | OEM Verified |
Show expert analysisTechnical: **Running load:** 1320W (OEM published). **Startup surge:** 6800W (OEM published, 5.15x running). **Voltage:** 120V AC. Oil-free pump, 0.8 HP motor, 150 PSI max. This is the only variant in this set with OEM-published starting watts. Field note: The CRAFTSMAN OEM data reveals a critical insight: pancake compressors surge at over 5x running watts โ far more than the 3x NEC assumption used for many motor loads. This is because the compressor must overcome residual tank pressure on restart. Always size for the 6800W surge, not the 1320W running draw. Why does this compressor need so much more starting power than running power? The motor must overcome compressed air resistance in the tank at startup. CRAFTSMAN rates this model at 6800W starting versus 1320W running โ a 5.15x ratio. Most power stations under 3500W surge will fail to start this compressor. | |||||
| Metabo HPT EC914S 'The Tank' (6-Gal, 1.3 HP, 200 PSI) | 1,620W | 8,343W | Safe | ~2.7h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 1620W from OEM rated amps (13.5A ร 120V). **Estimated startup surge:** 8343W at 5.15x running (proxy from CRAFTSMAN OEM data for comparable 6-gallon pancake compressor โ no Metabo HPT starting watts published). **Voltage:** 120V AC. Industrial motor, 1.3 HP, 200 PSI max โ the most powerful unit in this set. Field note: The EC914S draws 35% more running watts and has an estimated 8343W surge โ this is the hardest-to-run pancake compressor in the set. Most consumer power stations cannot start it. Its 200 PSI max and 4.0 SCFM output make it a jobsite-grade tool that demands jobsite-grade power. Why does the Metabo HPT need so much more power than the DeWalt? At 1.3 HP versus 0.9 HP, the EC914S delivers 54% more air flow and 21% higher max pressure. That extra performance requires 1620W running and an estimated 8343W startup surge โ significantly more than entry-level 0.8-0.9 HP compressors. | |||||
This unit ranks #3 of 3 compatible generators for this device by buffered margin (Overkill class).
3 of 33 generators are SAFE+TIGHT for Pancake Air Compressor (6-Gallon).
Fit class uses buffered needs (running and surge) for this device.
Tire Inflation and Tools
Select Your Model:
Free Tools
With 24,000W surge capacity, this system can handle typical compressor startup events found in central air conditioners, well pumps, and refrigeration equipment. The 12,000W continuous rating supports sustained high-load operation across multiple circuits. At 6,144Wh usable capacity, runtime depends on connected load, but this configuration can support whole-home essentials during extended outages.
This unit uses LFP chemistry, a formulation widely recognized for thermal stability in residential backup applications. The manufacturer provides operational guidelines in their documentation, and users should follow all installation and grounding instructions. Source: EcoFlow DELTA Pro Ultra X User Manual (manufacturer documentation).
Keep your Pancake Air Compressor (6-Gallon) running with solar โข MPPT: 80โ 500V โข Max: 10000W
Official 400W Panel
Requires 2 panels in series to reach the 80V start threshold.
Smart Value 400W Panel
Requires 2 panels in series to reach the 80V start threshold.
Smart Value 350W Panel
Requires 3 panels in series to reach the 80V start threshold.
Yes. The EcoFlow Delta Pro Ultra X provides 12000W running / 24000W surge. The Pancake Air Compressor (6-Gallon) needs 2025W / 10429W (including 25% buffer). That leaves 9975W of running headroom and 13571W of surge margin.
Approximately 2.7 hours, based on the Pancake Air Compressor (6-Gallon)'s 1620W draw and the Delta Pro Ultra X's 6144Wh capacity (70% usable after real-world losses).
With 1965W allocated to the Pancake Air Compressor (6-Gallon), the Delta Pro Ultra X still has ~6015W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your Delta Pro Ultra X, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Pancake Air Compressor (6-Gallon)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Metabo HPT EC914S (1620W). Surge worst case = Metabo HPT EC914S (8343W). Surge ratio 5.15x derived from CRAFTSMAN CMEC6150 OEM-published start/run watts (6800W/1320W).
EcoFlow DELTA Pro Ultra X User Manual
Similar-output alternatives you can compare side by side.