Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V/240V available
This pairing clears the safety headroom. Required ~330W running and 330W surge; the DELTA Pro 3 is rated 4000W / 8000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V/240V available
Continuous draw with safety buffer applied.
330W required -> 4,000W available (3,670W headroom)
Startup peak with safety buffer applied.
330W required -> 8,000W available (7,670W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 9.6h
Device profile reference: up to 6h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Crock-Pot 7-Quart Manual Slow Cooker (SAP_2131381) (300W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Crock-Pot 6-Quart Cook and Carry (SCCPVL610SA) | 240W | 240W | Safe | ~11.9h | OEM Verified |
Show expert analysisTechnical: **Running load:** 240 W. **Surge:** 240 W (no inrush spike). **Voltage:** 120 V AC required. Resistive heating element draws steady current with no motor or compressor startup transient. Field note: Verify power station AC inverter capacity exceeds 240 W continuous rating. Reserve at least 20% headroom (300 W minimum inverter rating) for thermal stability during extended runtime. Can I run this slow cooker on a portable power station all day? Only if your power source can supply at least 240W continuous and 240W surge at 120V. | |||||
| Crock-Pot 7-Quart Manual Slow Cooker (SAP_2131381) | 300W | 300W | Safe | ~9.6h | OEM Verified |
Show expert analysisTechnical: **Running load:** 300 W. **Surge:** 300 W (resistive heating element, no motor startup). **Voltage:** 120 V AC required. Power station must sustain 300 W continuous output at 120 V for safe operation. Field note: Verify power station rated capacity exceeds 1800 Wh if running the full daily cycle. Add 10-15% margin for inverter efficiency losses. Can I cook an 8-hour recipe on a single charge? Only if your power source can supply at least 300W continuous and 300W surge at 120V. It depends on the power station's usable capacity. An 8-hour cook cycle requires 2400 Wh minimum, plus inverter overhead. Verify your unit's rated watt-hours before planning extended recipes. | |||||
| Crock-Pot 4.5-Quart Manual Slow Cooker (SAP_2131365) | 210W | 210W | Safe | ~13.7h | OEM Verified |
Show expert analysisTechnical: **Running load:** 210 W. **Surge:** 210 W (resistive heating element, no inrush). **Voltage:** 120 V AC required. Power station must deliver clean 120 V output and at least 210 W continuous capacity. Field note: Verify power station capacity exceeds 1260 Wh if running a full daily cook cycle on battery alone. Leave 15 percent headroom for inverter efficiency loss. Can I run this slow cooker for 8 hours on a 1500 Wh power station? Only if your power source can supply at least 210W continuous and 210W surge at 120V. | |||||
This unit ranks #30 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for Slow Cooker.
Fit class uses buffered needs (running and surge) for this device.
All-Day Slow Cooking
Select Your Model:
Free Tools
The 8000W surge rating can support typical compressor startup in residential air conditioners, well pumps, and refrigeration equipment. Most single-phase motor loads under 2HP can start on this surge budget. The 4000W continuous capacity can handle simultaneous operation of multiple circuits including HVAC blowers, lighting, and standard appliances during extended outages.
This unit provides 4096Wh of LFP battery capacity with 4000W continuous and 8000W surge output capability. Source: EcoFlow DELTA Pro 3 User Manual v1.1 (AC Output Specifications) (manufacturer documentation). The LFP chemistry offers thermal stability compared to older lithium-ion chemistries, though all battery systems require proper ventilation and adherence to installation guidelines.
Keep your Slow Cooker running with solar โข MPPT: 30โ 150V โข Max: 2600W
Official 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 350W Panel
Adapter required: MC4 -> XT60.
Yes. The EcoFlow DELTA Pro 3 provides 4000W running / 8000W surge. The Slow Cooker needs 330W / 330W (including 10% buffer). That leaves 3670W of running headroom and 7670W of surge margin.
Approximately 9.6 hours, based on the Slow Cooker's 300W draw and the DELTA Pro 3's 4096Wh capacity (70% usable after real-world losses).
With 2080W allocated to the Slow Cooker, the DELTA Pro 3 still has ~820W of margin. These devices could run simultaneously:
Efficiency Hack: Large appliances like the Slow Cooker cycle on and off. To maximize the 9.6 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the Slow Cooker
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Crock-Pot 7-Quart Manual Slow Cooker (SAP_2131381) (300W). Surge = running (resistive heating element โ no motor inrush).
EcoFlow DELTA Pro 3 User Manual v1.1 (AC Output Specifications)
Similar-output alternatives you can compare side by side.