Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
3 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,100W to 1,981W required -> 1,800W available (700W headroom on lighter models)
Startup peak with safety buffer applied.
1,100W to 1,981W required -> 3,600W available (1,619W to 2,500W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.4h
Device profile reference: up to 1h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Duxtop Portable Induction Cooktop (1800W) (1,800W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Duxtop Portable Induction Cooktop (1800W) | 1,800W | 1,800W | Tight | ~0.4h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1800 W. **Surge:** 1800 W (resistive heating element, no inrush spike). **Voltage:** 120 V AC required. Power station must sustain 1800 W continuous output on AC inverter. Field note: Verify power station inverter rating is at least 2000 W continuous to allow headroom. Resistive load provides stable draw without cyclic spikes. Can I run this induction cooktop on a 1500 W power station? Only if your power source can supply at least 1800W continuous and 1800W surge at 120V. | |||||
| Cuisinart CB-30 Cast-Iron Single Burner | 1,300W | 1,300W | Safe | ~0.6h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1300 W at 120V. **Surge:** 1300 W (resistive heating element, no motor startup). Requires power station with continuous 1300 W rating and 120V AC outlet. Field note: Verify power station continuous output meets or exceeds 1300 W. Insufficient headroom will trigger overload shutdown during cooking. Can I use this burner with a 1000W power station? Only if your power source can supply at least 1300W continuous and 1300W surge at 120V. | |||||
| Ovente BGC101S Single Electric Burner | 1,000W | 1,000W | Safe | ~0.7h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1000 W. **Surge:** 1000 W. **Voltage:** 120 V AC. Resistive heating element draws steady current with no inrush spike. Power station must supply clean 120 V output and sustain 1000 W continuous. Field note: Verify power station AC outlet delivers rated continuous output. Undersized inverters will overheat or shut down under sustained resistive load. Can I use this burner with a 500 Wh portable power station? Only if your power source can supply at least 1000W continuous and 1000W surge at 120V. Runtime would be approximately 30 minutes before depletion, provided inverter does not thermally limit first. | |||||
This unit ranks #5 of 21 compatible generators for this device by buffered margin (Balanced class).
21 of 33 generators are SAFE+TIGHT for Electric Stove (Single Burner).
Fit class uses buffered needs (running and surge) for this device.
Portable Cooking
Select Your Model:
This load may exceed a standard 15A outlet. Verify your station has a higher-amperage outlet (20A/30A) before purchase.
Free Tools
The 3600W surge capacity can support typical residential motor startup scenarios including refrigerator compressors, well pumps, and power tools with inductive loads. The 1024Wh capacity sustains the 1800W continuous rating for approximately 34 minutes at full draw. This configuration can handle brief high-demand events common in backup power and job site applications.
LFP chemistry provides stable electrochemical performance under load cycling. The 3600W surge rating indicates transient overcurrent capability designed for inductive startup events. Source: EcoFlow DELTA 3 Plus User Manual v1.0 (Output Specs Section) (manufacturer documentation). Users must verify that connected equipment falls within these published limits.
Keep your Electric Stove (Single Burner) running with solar โข MPPT: 11โ 60V โข Max: 1000W
Official 400W Panel
Adapter required: MC4 -> XT60i.
Smart Value 350W Panel
Adapter required: MC4 -> XT60i.
Smart Value 200W Panel
Adapter required: MC4 -> XT60i.
It depends on the model. 3 of 3 Electric Stove (Single Burner) models are compatible with the EcoFlow DELTA 3 Plus. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 0.4โ0.7 hours on the DELTA 3 Plus. 0 of 3 models are not compatible. See the model-specific results for details.
Efficiency Hack: Large appliances like the Electric Stove (Single Burner) cycle on and off. To maximize the 0.4 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the Electric Stove (Single Burner)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Duxtop Portable Induction Cooktop 1800W (1800W). Surge = running (resistive heating element โ no motor inrush).
EcoFlow DELTA 3 Plus User Manual
Similar-output alternatives you can compare side by side.