Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
This pairing clears the safety headroom. Required ~1871W running and 1871W surge; the DELTA 2 Max is rated 2400W / 4800W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,871W required -> 2,400W available (529W headroom)
Startup peak with safety buffer applied.
1,871W required -> 4,800W available (2,929W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.8h
Device profile reference: up to 0.5h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Instant Pot Vortex Plus 6QT (1,700W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Instant Pot Vortex Plus 6QT | 1,700W | 1,700W | Safe | ~0.8h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1700W. **Surge:** 1700W. **Voltage:** 120V AC. No surge overhead indicates resistive heating element with minimal inrush. Power station must supply continuous 1700W on a single AC outlet. Field note: Verify your power station's continuous AC output rating exceeds 1700W with margin for voltage sag under load. Can I run this air fryer on a 1500W power station? Only if your power source can supply at least 1700W continuous and 1700W surge at 120V. Only if the station tolerates brief overload without shutdown. | |||||
| Cosori Pro II 5.8-Quart (CS358-AF) | 1,700W | 1,700W | Safe | ~0.8h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1700 W. **Surge:** 1700 W (resistive heating element, no startup spike). **Voltage:** 120V AC required. Power station must deliver steady 1700 W continuous output at 120V. Field note: Verify power station sustains 1700 W continuous without voltage sag. Match or exceed rated output capacity. Can I run this air fryer on a 1500W power station? Only if your power source can supply at least 1700W continuous and 1700W surge at 120V. Only if you accept nuisance shutdowns or reduced cooking performance. | |||||
| Ninja AF101 (AF100 Series) | 1,550W | 1,550W | Safe | ~0.9h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1550 W. **Surge:** 1550 W (no inrush spike). **Voltage:** 120 V AC. Resistive heating element, stable draw throughout cook cycle. Field note: Size the power station with at least 1600 W continuous output. Check AC outlet rating, not just inverter nameplate capacity. Will this air fryer work on a 1000 W power station? Only if your power source can supply at least 1550W continuous and 1550W surge at 120V. | |||||
This unit ranks #11 of 21 compatible generators for this device by buffered margin (Overkill class).
21 of 33 generators are SAFE+TIGHT for Digital Air Fryer.
Fit class uses buffered needs (running and surge) for this device.
Healthy Quick Cooking
Select Your Model:
Free Tools
The 4800 W surge can support typical startup loads for refrigerators, well pumps, and air compressor motors that require momentary inrush current. The 2048 Wh capacity provides extended runtime for moderate continuous loads. This configuration can handle brief motor starts while sustaining steady power delivery for home backup scenarios.
This unit uses LFP chemistry, which offers a different thermal profile than older lithium chemistries. The manufacturer provides operational guidelines in their documentation. Source: EcoFlow DELTA 2 Max User Manual v1.0 (manufacturer documentation). Follow all usage instructions to maintain safe operation.
Keep your Digital Air Fryer running with solar โข MPPT: 11โ 60V โข Max: 1000W
Official 400W Panel
Adapter required: MC4 -> XT60i.
Smart Value 350W Panel
Adapter required: MC4 -> XT60i.
Smart Value 200W Panel
Adapter required: MC4 -> XT60i.
Yes. The EcoFlow DELTA 2 Max provides 2400W running / 4800W surge. The Digital Air Fryer needs 1871W / 1871W (including 10% buffer). That leaves 529W of running headroom and 2929W of surge margin.
Approximately 0.8 hours, based on the Digital Air Fryer's 1700W draw and the DELTA 2 Max's 2048Wh capacity (70% usable after real-world losses).
With 215W allocated to the Digital Air Fryer, the DELTA 2 Max still has ~5W of margin. These devices could run simultaneously:
Efficiency Hack: Large appliances like the Digital Air Fryer cycle on and off. To maximize the 0.8 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the Digital Air Fryer
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Instant Pot Vortex Plus 6QT (1700W). Surge = running (resistive heating element โ no motor inrush).
EcoFlow DELTA 2 Max User Manual v1.0
Similar-output alternatives you can compare side by side.