Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
Note: You are viewing specs for the original DELTA (Gen 1)
This legacy model has been officially replaced by a newer version with improved specs.
3 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
1,100W to 1,981W required -> 1,800W available (700W headroom on lighter models)
Startup peak with safety buffer applied.
1,100W to 1,981W required -> 3,300W available (1,319W to 2,200W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.5h
Device profile reference: up to 1h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Duxtop Portable Induction Cooktop (1800W) (1,800W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Duxtop Portable Induction Cooktop (1800W) | 1,800W | 1,800W | Tight | ~0.5h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1800 W. **Surge:** 1800 W (resistive heating element, no inrush spike). **Voltage:** 120 V AC required. Power station must sustain 1800 W continuous output on AC inverter. Field note: Verify power station inverter rating is at least 2000 W continuous to allow headroom. Resistive load provides stable draw without cyclic spikes. Can I run this induction cooktop on a 1500 W power station? Only if your power source can supply at least 1800W continuous and 1800W surge at 120V. | |||||
| Cuisinart CB-30 Cast-Iron Single Burner | 1,300W | 1,300W | Safe | ~0.7h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1300 W at 120V. **Surge:** 1300 W (resistive heating element, no motor startup). Requires power station with continuous 1300 W rating and 120V AC outlet. Field note: Verify power station continuous output meets or exceeds 1300 W. Insufficient headroom will trigger overload shutdown during cooking. Can I use this burner with a 1000W power station? Only if your power source can supply at least 1300W continuous and 1300W surge at 120V. | |||||
| Ovente BGC101S Single Electric Burner | 1,000W | 1,000W | Safe | ~0.9h | OEM Manual |
Show expert analysisTechnical: **Running load:** 1000 W. **Surge:** 1000 W. **Voltage:** 120 V AC. Resistive heating element draws steady current with no inrush spike. Power station must supply clean 120 V output and sustain 1000 W continuous. Field note: Verify power station AC outlet delivers rated continuous output. Undersized inverters will overheat or shut down under sustained resistive load. Can I use this burner with a 500 Wh portable power station? Only if your power source can supply at least 1000W continuous and 1000W surge at 120V. Runtime would be approximately 30 minutes before depletion, provided inverter does not thermally limit first. | |||||
This unit ranks #4 of 21 compatible generators for this device by buffered margin (Balanced class).
21 of 33 generators are SAFE+TIGHT for Electric Stove (Single Burner).
Fit class uses buffered needs (running and surge) for this device.
Portable Cooking
Select Your Model:
This load may exceed a standard 15A outlet. Verify your station has a higher-amperage outlet (20A/30A) before purchase.
Free Tools
The 3300W surge capacity can handle typical startup demands from refrigerators, well pumps, and other motor-driven appliances that require brief inrush current. The 1800W continuous rating supports sustained loads like power tools, kitchen appliances, and electronics. Understand that this is a legacy unit no longer in active production.
This legacy model uses NMC lithium chemistry in a 1260Wh battery pack. The manufacturer documentation outlines operational guidelines and user precautions for safe charging and discharging cycles. Source: EcoFlow DELTA 1300 User Manual (manufacturer documentation). This model has been discontinued and replaced by newer generations.
Keep your Electric Stove (Single Burner) running with solar โข MPPT: 10โ 65V โข Max: 400W
Official 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 350W Panel
Adapter required: MC4 -> XT60.
Smart Value 200W Panel
Adapter required: MC4 -> XT60.
It depends on the model. 3 of 3 Electric Stove (Single Burner) models are compatible with the EcoFlow DELTA (Gen 1). See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 0.5โ0.9 hours on the DELTA (Gen 1). 0 of 3 models are not compatible. See the model-specific results for details.
Efficiency Hack: Large appliances like the Electric Stove (Single Burner) cycle on and off. To maximize the 0.5 hours of runtime, try to minimize how often you open the device or introduce heat loads.
Compare all 33 generators for the Electric Stove (Single Burner)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Duxtop Portable Induction Cooktop 1800W (1800W). Surge = running (resistive heating element โ no motor inrush).
EcoFlow DELTA 1300 User Manual (V1.0)
Similar-output alternatives you can compare side by side.