Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
Note: You are viewing specs for the original DELTA (Gen 1)
This legacy model has been officially replaced by a newer version with improved specs.
1 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
863W to 1,075W required -> 1,800W available (725W to 937W headroom)
Startup peak with safety buffer applied.
3,225W to 4,169W required -> 3,300W available (75W headroom on lighter models)
Alternative startup path with reduced inrush.
1,876W required -> 3,300W available (1,424W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 1.0h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
1 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea EasyDry MDP70SR71 (70 Pint) | 690W | 3,335W | Soft Start | ~1.3h | OEM Manual |
Show expert analysisTechnical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โฅ3335W and continuous output โฅ690W are candidates. Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably. Can I run this dehumidifier on a portable power station overnight? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size. | |||||
| Midea EasyDry MDP70PR71 with Pump (70 Pint) | 690W | 3,335W | Soft Start | ~1.3h | OEM Manual |
Show expert analysisTechnical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection. Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw. Can I run this dehumidifier on a portable power station? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement. | |||||
| Haier HEN70ETF (70 Pint) | 860W | 2,580W | Safe | ~1.0h | OEM Verified |
Show expert analysisTechnical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping. Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw. Can I run this dehumidifier overnight on a portable power station? Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control. | |||||
This unit is borderline without mitigation; 17 of 33 generators meet SAFE/TIGHT margins for this device.
17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).
Fit class uses buffered needs (running and surge) for this device.
Basement Moisture Control
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
The 3300W surge capacity can handle typical startup demands from refrigerators, well pumps, and other motor-driven appliances that require brief inrush current. The 1800W continuous rating supports sustained loads like power tools, kitchen appliances, and electronics. Understand that this is a legacy unit no longer in active production.
This legacy model uses NMC lithium chemistry in a 1260Wh battery pack. The manufacturer documentation outlines operational guidelines and user precautions for safe charging and discharging cycles. Source: EcoFlow DELTA 1300 User Manual (manufacturer documentation). This model has been discontinued and replaced by newer generations.
Keep your Dehumidifier (70 Pint) running with solar โข MPPT: 10โ 65V โข Max: 400W
Official 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 350W Panel
Adapter required: MC4 -> XT60.
Smart Value 200W Panel
Adapter required: MC4 -> XT60.
It depends on the model. 1 of 3 Dehumidifier (70 Pint) models are compatible with the EcoFlow DELTA (Gen 1). See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 1.0โ1.3 hours on the DELTA (Gen 1). 0 of 3 models are not compatible. See the model-specific results for details.
With 495W allocated to the Dehumidifier (70 Pint), the DELTA (Gen 1) still has ~85W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your DELTA (Gen 1), keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Dehumidifier (70 Pint)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).
EcoFlow DELTA 1300 User Manual (V1.0)