Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
1 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
932W to 1,217W required -> 1,000W available (68W headroom on lighter models)
Startup peak with safety buffer applied.
1,681W to 2,795W required -> 2,000W available (319W headroom on lighter models)
Alternative startup path with reduced inrush.
1,258W required -> 2,000W available (742W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.5h
Device profile reference: up to 8h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
1 of 3 models are SAFE or TIGHT. Most demanding model: Goodman GMH8 0805B (80,000 BTU) (2,430W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Carrier Infinity 59MN7A 080 (80,000 BTU) | 886W | 1,461W | Tight | ~0.6h | OEM Manual |
Show expert analysisTechnical: **Running load:** 886W (115V ร 7.7A FLA, OEM rated). **Surge:** 1,461W (115V ร 12.7A start amps, OEM rated). **Voltage:** 120V AC. The ECM variable speed blower ramps up electronically with a controlled startup โ the 1,461W surge is brief and predictable. Field note: The Carrier Infinity is the most generator-friendly furnace blower in this comparison. The ECM variable speed motor keeps both running and surge watts low. Most power stations above 1,500W can handle this unit without issue. Can I run a Carrier Infinity furnace on a portable power station during a winter outage? Only if your power source can supply at least 886W continuous and 1,461W surge at 120V. The ECM variable speed blower has a controlled startup that most mid-size power stations can handle. | |||||
| Trane S8X1 B080 (80,000 BTU) | 1,058W | 1,587W | Fail | โ | Engineering Est. |
Show expert analysisTechnical: **Running load:** 1,058W (115V ร 9.2A FLA, OEM rated). **Surge:** 1,587W estimated (1.5ร for ECM constant torque motor โ OEM start amps not published). **Voltage:** 120V AC. The 3/4 HP constant torque ECM blower draws more than the Carrier variable speed but still benefits from electronic startup control. Field note: The Trane S8X1 is a mid-range 80% AFUE furnace common in existing homes. The 9-speed ECM blower is more efficient than old PSC motors but draws more than premium variable speed models. A 2,000W power station provides adequate headroom. Can I keep my Trane furnace running on battery backup during a winter storm? Only if your power source can supply at least 1,058W continuous and 1,587W surge at 120V. The ECM blower has a moderate startup demand that most 2,000W+ power stations can handle. | |||||
| Goodman GMH8 0805B (80,000 BTU) | 810W | 2,430W | Soft Start | ~0.7h | NEC Standard |
Show expert analysisTechnical: **Running load:** 810W (derived from OEM Min Circuit Ampacity 8.8A de-rated by NEC 1.25ร factor). **Surge:** 2,430W (3ร running per NEC for PSC induction motor โ OEM LRA not published). **Voltage:** 120V AC. The 4-speed PSC motor creates a hard mechanical inrush on every startup โ three times the running load. Field note: The Goodman GMH8 represents millions of builder-grade furnaces installed across the US. The PSC motor surge is the critical factor โ running watts are actually lower than ECM models, but the 2,430W startup spike will trip any power station under 2,500W. This is the #1 reason furnace blowers fail on small generators. Why does my power station shut off when the Goodman furnace blower starts? Because the PSC blower motor creates a 2,430W startup surge โ 3ร its 810W running draw. Most power stations under 2,500W surge capacity will trip on this inrush. You need a station rated for at least 2,430W surge to handle it reliably. | |||||
This unit is outside the compatible set; 22 of 33 generators pass SAFE/TIGHT for this device.
22 of 33 generators are SAFE+TIGHT for Gas Furnace Fan (Blower).
Fit class uses buffered needs (running and surge) for this device.
Winter Heating Emergency
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
With 2000W of surge capacity, the AC70 can handle typical startup transients from refrigerators, well pumps, and other inductive motor loads that demand brief high-current events. The 768Wh capacity supports extended runtime for moderate continuous loads. This combination allows the unit to start compressor equipment that would otherwise exceed its 1000W running rating.
This unit uses lithium iron phosphate (LFP) chemistry, known for structural stability under thermal stress. The manufacturer provides operational specifications through official documentation. Source: BLUETTI AC70 User Manual Specs (manufacturer documentation). No independent safety certification details are provided in the available data.
Keep your Gas Furnace Fan (Blower) running with solar โข MPPT: 12โ 58V โข Max: 500W
Official 350W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 200W Panel
Adapter required: MC4 -> XT60.
It depends on the model. 1 of 3 Gas Furnace Fan (Blower) models are compatible with the Bluetti AC70. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 0.6โ0.7 hours on the AC70. 1 of 3 models are not compatible. See the model-specific results for details.
Power Tip: To get the most out of your AC70, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Gas Furnace Fan (Blower)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Worst case running = Trane S8X1 B080 (1058W). Worst case surge = Goodman GMH8 080 (2430W). Running and surge maxima come from different variants due to ECM vs PSC motor technology.
BLUETTI AC70 User Manual
Similar-output alternatives you can compare side by side.