Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
0 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
863W to 1,075W required -> 1,000W available (137W headroom on lighter models)
Startup peak with safety buffer applied.
3,225W to 4,169W required -> 2,000W available (1,225W to 2,169W short)
Alternative startup path with reduced inrush.
1,876W required -> 2,000W available (124W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.6h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
See soft-start optionsQuick compatibility, required headroom, and model-specific context at a glance.
0 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea EasyDry MDP70SR71 (70 Pint) | 690W | 3,335W | Soft Start | ~0.8h | OEM Manual |
Show expert analysisTechnical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โฅ3335W and continuous output โฅ690W are candidates. Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably. Can I run this dehumidifier on a portable power station overnight? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size. | |||||
| Midea EasyDry MDP70PR71 with Pump (70 Pint) | 690W | 3,335W | Soft Start | ~0.8h | OEM Manual |
Show expert analysisTechnical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection. Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw. Can I run this dehumidifier on a portable power station? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement. | |||||
| Haier HEN70ETF (70 Pint) | 860W | 2,580W | Fail | โ | OEM Verified |
Show expert analysisTechnical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping. Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw. Can I run this dehumidifier overnight on a portable power station? Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control. | |||||
This unit is outside the compatible set; 17 of 33 generators pass SAFE/TIGHT for this device.
17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).
Fit class uses buffered needs (running and surge) for this device.
Basement Moisture Control
Select Your Model:
โก Soft-Starter Required
The Dehumidifier (70 Pint)'s startup surge (3335W) exceeds this generator's capacity. A soft-starter can reduce inrush current by ~55%, bringing surge down to approximately 1501W.
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Prefer not to install a soft starter on Dehumidifier (70 Pint)? These generators can start this load natively.
3000W โข 2042Wh
Lowest capacity that still clears surge + running load.
3600W โข 3600Wh
Expandable to 25000Wh.
Free Tools
With 2000W of surge capacity, the AC70 can handle typical startup transients from refrigerators, well pumps, and other inductive motor loads that demand brief high-current events. The 768Wh capacity supports extended runtime for moderate continuous loads. This combination allows the unit to start compressor equipment that would otherwise exceed its 1000W running rating.
This unit uses lithium iron phosphate (LFP) chemistry, known for structural stability under thermal stress. The manufacturer provides operational specifications through official documentation. Source: BLUETTI AC70 User Manual Specs (manufacturer documentation). No independent safety certification details are provided in the available data.
Keep your Dehumidifier (70 Pint) running with solar โข MPPT: 12โ 58V โข Max: 500W
Official 350W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 200W Panel
Adapter required: MC4 -> XT60.
It depends on the model. 0 of 3 Dehumidifier (70 Pint) models are compatible with the Bluetti AC70. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 0.8โ0.8 hours on the AC70. 1 of 3 models are not compatible. See the model-specific results for details.
Power Tip: To get the most out of your AC70, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Dehumidifier (70 Pint)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).
BLUETTI AC70 User Manual
Similar-output alternatives you can compare side by side.