Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
This pairing clears the safety headroom. Required ~96W running and 191W surge; the AC70 is rated 1000W / 2000W.
Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
96W required -> 1,000W available (904W headroom)
Startup peak with safety buffer applied.
191W required -> 2,000W available (1,809W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 6.5h
Device profile reference: up to 8h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
3 of 3 models are SAFE or TIGHT. Most demanding model: Lasko B20200 (20-inch Box Fan) (166W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Lasko B20200 (20-inch Box Fan) | 83W | 166W | Safe | ~6.5h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 83 W. **Surge:** 166 W (estimated 2x startup for shaded-pole motor). **Voltage:** 120 V AC. Small shaded-pole fan motors produce a brief inrush at startup that is typically 2x running โ far less than the 3x NEC standard for larger motors. Field note: Box fans are among the easiest appliances to run off-grid. Even with the 2x startup surge, any power station rated 200W+ handles this fan comfortably. Will this fan drain my power station quickly? At 83W continuous, an 8-hour overnight run consumes ~664 Wh. A 1000Wh power station handles it with margin to spare. | |||||
| Lasko B20500 (20-inch Box Fan) | 72W | 144W | Safe | ~7.5h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 72 W. **Surge:** 144 W (estimated 2x startup). **Voltage:** 120 V AC. Slightly lower draw than the B20200 โ same motor technology, lower speed setting or blade design. Field note: At 72W, this is the lightest box fan in the comparison. Perfect for overnight use on a portable power station โ a 500Wh unit runs it for nearly 7 hours. Can I run this fan overnight on a 500 Wh power station? Close โ 8 hours at 72W needs 576 Wh. With inverter losses (~70% usable), a 500Wh station runs it for about 5 hours. A 750Wh+ station covers a full night. | |||||
| Lasko 3733 (20-inch Box Fan) | 80W | 160W | Safe | ~6.7h | Engineering Est. |
Show expert analysisTechnical: **Running load:** 80 W (high speed, top of 50-80W range). **Surge:** 160 W (estimated 2x startup). **Voltage:** 120 V AC. Variable speed range means actual draw depends on setting โ low speed draws as little as 50W. Field note: If running on battery, use a lower speed setting. Dropping from high (80W) to low (50W) extends runtime by 60% โ a meaningful difference on a single charge. How long can I run this fan on low speed? At 50W on low speed, a 1000Wh power station (700Wh usable) runs it for about 14 hours. High speed (80W) cuts that to about 9 hours. | |||||
This unit ranks #10 of 33 compatible generators for this device by buffered margin (Overkill class).
33 of 33 generators are SAFE+TIGHT for Box Fan (20-inch).
Fit class uses buffered needs (running and surge) for this device.
Hot Weather Ventilation
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
With 2000W of surge capacity, the AC70 can handle typical startup transients from refrigerators, well pumps, and other inductive motor loads that demand brief high-current events. The 768Wh capacity supports extended runtime for moderate continuous loads. This combination allows the unit to start compressor equipment that would otherwise exceed its 1000W running rating.
This unit uses lithium iron phosphate (LFP) chemistry, known for structural stability under thermal stress. The manufacturer provides operational specifications through official documentation. Source: BLUETTI AC70 User Manual Specs (manufacturer documentation). No independent safety certification details are provided in the available data.
Keep your Box Fan (20-inch) running with solar โข MPPT: 12โ 58V โข Max: 500W
Official 350W Panel
Adapter required: MC4 -> XT60.
Smart Value 400W Panel
Adapter required: MC4 -> XT60.
Smart Value 200W Panel
Adapter required: MC4 -> XT60.
Yes. The Bluetti AC70 provides 1000W running / 2000W surge. The Box Fan (20-inch) needs 96W / 191W (including 15% buffer). That leaves 904W of running headroom and 1809W of surge margin.
Approximately 6.5 hours, based on the Box Fan (20-inch)'s 83W draw and the AC70's 768Wh capacity (70% usable after real-world losses).
With 525W allocated to the Box Fan (20-inch), the AC70 still has ~192W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your AC70, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Box Fan (20-inch)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Lasko B20200 (83W OEM). Surge worst case = Lasko B20200 (166W). Small fan motor policy: 2x startup for shaded-pole motors.
BLUETTI AC70 User Manual