Voltage Gate
PASSDevice output type must match generator output.
120V required -> 120V available
1 of 3 models are compatible with this generator.
Jump to model-specific results โSame decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.
Device output type must match generator output.
120V required -> 120V available
Continuous draw with safety buffer applied.
863W to 1,075W required -> 1,800W available (725W to 937W headroom)
Startup peak with safety buffer applied.
3,225W to 4,169W required -> 2,700W available (525W to 1,469W short)
Alternative startup path with reduced inrush.
1,876W required -> 2,700W available (824W headroom)
Runtime context only. It does not change the electrical compatibility verdict.
Continuous estimate: 0.9h
Device profile reference: up to 24h per day.
Power bars show required versus available output for each gate.
View full compatibility reportQuick compatibility, required headroom, and model-specific context at a glance.
1 of 3 models are SAFE or TIGHT. Most demanding model: Midea EasyDry MDP70SR71 (70 Pint) (3,335W surge).
| Model | Running | Surge | Verdict | Runtime | Source |
|---|---|---|---|---|---|
| Midea EasyDry MDP70SR71 (70 Pint) | 690W | 3,335W | Soft Start | ~1.2h | OEM Manual |
Show expert analysisTechnical: **Voltage:** 120V AC required. **Running load:** 690W. **Surge:** 3335W at startup (compressor-driven). Only power stations with inverter surge capacity โฅ3335W and continuous output โฅ690W are candidates. Field note: Verify the power station's surge window duration. Short-duration surge ratings may not accommodate refrigerant compressor startup transients reliably. Can I run this dehumidifier on a portable power station overnight? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. It depends on the station's surge capacity and battery size. | |||||
| Midea EasyDry MDP70PR71 with Pump (70 Pint) | 690W | 3,335W | Soft Start | ~1.2h | OEM Manual |
Show expert analysisTechnical: **Running load:** 690 W. **Surge demand:** 3,335 W at compressor start. Requires 120V AC output. Power station must deliver the full surge envelope without tripping overcurrent protection. Field note: Ensure your power station's inverter can handle the 3,335 W surge without shutdown. Verify outlet capacity exceeds continuous draw. Can I run this dehumidifier on a portable power station? Only if your power source can supply at least 690W continuous and 3335W surge at 120V. Most portable units cannot meet the surge requirement. | |||||
| Haier HEN70ETF (70 Pint) | 860W | 2,580W | Tight | ~0.9h | OEM Verified |
Show expert analysisTechnical: **Running load:** 860W. **Surge:** 2580W at startup. Requires 120V AC output. Power station must sustain 860W continuous and handle 2580W compressor inrush without tripping. Field note: Size the power station to at least 125% of running load (1075W minimum output) to avoid nuisance shutdowns during concurrent household draw. Can I run this dehumidifier overnight on a portable power station? Only if your power source can supply at least 860W continuous and 2580W surge at 120V. Most portable units lack sufficient capacity for full-day basement moisture control. | |||||
This unit is borderline without mitigation; 17 of 33 generators meet SAFE/TIGHT margins for this device.
17 of 33 generators are SAFE+TIGHT for Dehumidifier (70 Pint).
Fit class uses buffered needs (running and surge) for this device.
Basement Moisture Control
Select Your Model:
These systems are often hardwired to a home panel. To run them from a portable station, you may need a transfer switch installed by an electrician. You cannot just plug it in.
Free Tools
The 2700W surge window can handle typical compressor startup on refrigerators, freezers, and sump pumps where inrush current briefly exceeds running draw. The 1152Wh capacity supports extended runtime for lower-wattage essentials. This configuration can support residential backup scenarios where brief peak demand is predictable and within spec.
This unit uses LFP chemistry and provides manufacturer-rated surge capacity for inductive startup events. Always verify that your specific appliance falls within the rated limits before connection. Source: BLUETTI AC180 User Manual (manufacturer documentation).
Keep your Dehumidifier (70 Pint) running with solar โข MPPT: 12โ 60V โข Max: 500W
Official 350W Panel
Adapter required: MC4 -> DC7909.
Smart Value 400W Panel
Adapter required: MC4 -> DC7909.
Smart Value 200W Panel
Adapter required: MC4 -> DC7909.
It depends on the model. 1 of 3 Dehumidifier (70 Pint) models are compatible with the Bluetti AC180. See the model-specific results table for exact verdicts per model.
It depends on the model. Compatible models run approximately 0.9โ1.2 hours on the AC180. 0 of 3 models are not compatible. See the model-specific results for details.
With 325W allocated to the Dehumidifier (70 Pint), the AC180 still has ~255W of margin. These devices could run simultaneously:
Power Tip: To get the most out of your AC180, keep it in a well-ventilated area. Extreme temperatures can slightly reduce the efficiency of the LFP/NMC cells.
Compare all 33 generators for the Dehumidifier (70 Pint)
Ranked by budget, runtime, and overall compatibility.
Derived from variant list (max of variants). Running worst case = Haier HEN70ETF (860W). Surge worst case = Midea EasyDry MDP70SR71 (3335W).
BLUETTI AC180 User Manual