Yes, the Anker SOLIX F3800 can run an Electric Stove

This pairing clears the safety headroom. Required ~1981W running and 1981W surge; the Anker SOLIX F3800 is rated 6000W / 9000W.

Power Margin Analysis

6000W / 9000W Capacity
Running 4019W headroom
1981W required
Surge 7019W headroom
1981W required

Decision Gate Waterfall

Same decision gates as the engine: voltage, running, surge. Runtime is shown as operational context.

1

Voltage Gate

PASS

Device output type must match generator output.

120V required -> 120V/240V available

2

Running Gate

PASS

Continuous draw with safety buffer applied.

1,981W required -> 6,000W available (4,019W headroom)

Required 1,981W required
Available 6,000W
3

Surge Gate

PASS

Startup peak with safety buffer applied.

1,981W required -> 9,000W available (7,019W headroom)

Required 1,981W required
Available 9,000W
4

Runtime Insight

INFO

Runtime context only. It does not change the electrical compatibility verdict.

Continuous estimate: 1.5h

Device profile reference: up to 1h per day.

Power bars show required versus available output for each gate.

View full compatibility report

Decision Snapshot

Quick compatibility, required headroom, and model-specific context at a glance.

โšก
6000W
Running Power
๐Ÿ”‹
3840Wh
Capacity
โฑ๏ธ
~1.5h
Est. Runtime
โ˜€๏ธ
2400W
Solar Input

Quick Compatibility Check

  1. 1 Running headroom: target 1981W; generator provides 6000W.
  2. 2 Surge headroom: target 1981W; generator provides 9000W.
  3. 3 Tip: leave headroom for startup spikes and warm conditions.

Model-Specific Results

3 of 3 models are SAFE or TIGHT. Most demanding model: Duxtop Portable Induction Cooktop (1800W) (1,800W surge).

Model Running Surge Verdict Runtime Source
Duxtop Portable Induction Cooktop (1800W) 1,800W 1,800W Safe ~1.5h OEM Manual
Show expert analysis

Technical: **Running load:** 1800 W. **Surge:** 1800 W (resistive heating element, no inrush spike). **Voltage:** 120 V AC required. Power station must sustain 1800 W continuous output on AC inverter.

Field note: Verify power station inverter rating is at least 2000 W continuous to allow headroom. Resistive load provides stable draw without cyclic spikes.

Can I run this induction cooktop on a 1500 W power station?

Only if your power source can supply at least 1800W continuous and 1800W surge at 120V.

Cuisinart CB-30 Cast-Iron Single Burner 1,300W 1,300W Safe ~2.1h OEM Manual
Show expert analysis

Technical: **Running load:** 1300 W at 120V. **Surge:** 1300 W (resistive heating element, no motor startup). Requires power station with continuous 1300 W rating and 120V AC outlet.

Field note: Verify power station continuous output meets or exceeds 1300 W. Insufficient headroom will trigger overload shutdown during cooking.

Can I use this burner with a 1000W power station?

Only if your power source can supply at least 1300W continuous and 1300W surge at 120V.

Ovente BGC101S Single Electric Burner 1,000W 1,000W Safe ~2.7h OEM Manual
Show expert analysis

Technical: **Running load:** 1000 W. **Surge:** 1000 W. **Voltage:** 120 V AC. Resistive heating element draws steady current with no inrush spike. Power station must supply clean 120 V output and sustain 1000 W continuous.

Field note: Verify power station AC outlet delivers rated continuous output. Undersized inverters will overheat or shut down under sustained resistive load.

Can I use this burner with a 500 Wh portable power station?

Only if your power source can supply at least 1000W continuous and 1000W surge at 120V. Runtime would be approximately 30 minutes before depletion, provided inverter does not thermally limit first.

How This Pairing Performs Across Our Database

This unit ranks #19 of 21 compatible generators for this device by buffered margin (Overkill class).

How Electric Stove (Single Burner) Performs Across 33 Tested Generators

21 of 33 generators are SAFE+TIGHT for Electric Stove (Single Burner).

21 Safe+Tight
Safe 16 (48%)
Tight 5 (15%)
Fail 12 (36%)

Power Comparison: Anker SOLIX F3800 vs Top Alternatives for Electric Stove (Single Burner)

Fit class uses buffered needs (running and surge) for this device.

Specs & Surge Analysis

Electric Stove (Single Burner)
Kitchen Appliances

Electric Stove (Single Burner)

Portable Cooking

1800W
Running
1800W
Surge
120V
Required

True Surgeโ„ข Analysis

Safety Buffer: +10%
Running Power Usage 33% Utilization
1981W required 6000W Capacity
4019W headroom
Surge/Startup Peak 22% Utilization
1981W required 9000W Capacity
7019W headroom
Voltage Match 120V โ†” 120V/240V โœ“
โš ๏ธ Before You Buy: Connection Check
Amperage check

This load may exceed a standard 15A outlet. Verify your station has a higher-amperage outlet (20A/30A) before purchase.

Generator Insights

The 9000W surge rating can handle typical compressor-based appliances like central air conditioners, well pumps, and refrigerators during startup. This capacity can support multiple simultaneous high-draw devices once running loads stabilize. Expect reliable operation for tools, HVAC systems, and other inductive loads that demand short-duration power spikes.

This unit employs LFP chemistry with a 3840Wh capacity, designed for stable discharge under high-demand conditions. The architecture supports both sustained and transient loads within rated limits. Source: Anker SOLIX F3800 User Manual v1.1 (Specifications) (OEM documentation).

Extend Runtime with Solar

Keep your Electric Stove (Single Burner) running with solar โ€ข MPPT: 11โ€“ 60V โ€ข Max: 2400W

Anker undefined Official

Anker

100W Panel

1 Hour Sun =
+0h per sun hour
MC4 -> XT60
Full in ~54.9h

Adapter required: MC4 -> XT60.

EcoFlow undefined Smart Value

EcoFlow

400W Panel

1 Hour Sun =
+0.2h per sun hour
MC4 -> XT60
Full in ~13.7h

Adapter required: MC4 -> XT60.

EcoFlow undefined Smart Value

EcoFlow

400W Panel

1 Hour Sun =
+0.2h per sun hour
MC4 -> XT60
Full in ~13.7h

Adapter required: MC4 -> XT60.

Technical Analysis

Spec-Based โ€ข No Guarantees

Technical Breakdown

Running load: 1800 W. Surge: 1800 W (resistive heating element). Voltage: 120 V AC required. Power station must supply continuous 1800 W minimum.

Expected Behavior

Estimated runtime: ~1.5h. Resistive heating draws constant 1800 W when active. Daily usage of 1 hour consumes approximately 1800 Wh.

Field Note

Most induction cooktops offer adjustable power levels (200โ€“1800W). For RV or camping use, cooking on a lower setting (600โ€“800W) stretches battery runtime significantly while still bringing water to a boil. Many van lifers switching from propane to electric rely on this approach to stay within their station's capacity.

Frequently Asked Questions

Can the Anker SOLIX F3800 power an Electric Stove?

Yes. The Anker SOLIX F3800 provides 6000W running / 9000W surge. The Electric Stove (Single Burner) needs 1981W / 1981W (including 10% buffer). That leaves 4019W of running headroom and 7019W of surge margin.

How long will the Anker SOLIX F3800 run an Electric Stove?

Approximately 1.5 hours, based on the Electric Stove (Single Burner)'s 1800W draw and the Anker SOLIX F3800's 3840Wh capacity (70% usable after real-world losses).

What Else Can You Run?

With 2910W allocated to the Electric Stove (Single Burner), the Anker SOLIX F3800 still has ~90W of margin. These devices could run simultaneously:

๐Ÿฅ˜
Slow Cooker
200W
๐ŸงŠ
Portable Ice Maker
100W
โ˜•
Coffee Maker (Brew)
800W
๐Ÿซ–
Electric Kettle
1500W
๐Ÿ“บ
55' LED TV
80W
๐ŸŽฎ
Gaming Laptop
230W

Efficiency Hack: Large appliances like the Electric Stove (Single Burner) cycle on and off. To maximize the 1.5 hours of runtime, try to minimize how often you open the device or introduce heat loads.

Compare all 33 generators for the Electric Stove (Single Burner)

Ranked by budget, runtime, and overall compatibility.

See full ranking
Technical Sourcing & Verification
ID: anker-solix-f3800-electric-stove-single
๐Ÿ›๏ธ Device Data Source
Engineering Est. Safety Factor Applied

Derived from variant list (max of variants). Running worst case = Duxtop Portable Induction Cooktop 1800W (1800W). Surge = running (resistive heating element โ€” no motor inrush).

โšก Generator Specs Source
OEM Verified

Anker SOLIX F3800 User Manual v1.1 (Specifications)

Methodology informed by US Department of Energy (DOE) & EIA references where applicable. Our methodology โ†’

Compare these models

Similar-output alternatives you can compare side by side.