We tested 33 portable power stations against the Well Pump (1 HP) (2392W running / 7176W surge). 4 passed our True Surge protocol — 12% compatibility rate.
Safe
3
Tight
1
With Soft-Starter
1
Incompatible
28
Derived from variant list (max of variants). Worst case = Red Lion RL12G10-2W2V (2392W running, 7176W surge).
This device requires 240V split-phase power
Most consumer portable power stations output 120V only. The Well Pump (1 HP) is incompatible with any 120V-only unit regardless of wattage capacity.
Ranked by value, balance, and endurance from 3 compatible generators.
As an Amazon Associate, we earn from qualifying purchases. Our methodology
Runtime at a glance
How long each station runs a Well Pump on a single charge (after 0.70 real-world derate)
* Requires a soft-start device installed. Without one, these stations cannot handle the startup surge.
Running range: 1702W to 2392W across common 1 HP well pump designs. Startup range: 2553W to 7176W depending on motor/start behavior. Voltage: 240V class load in typical US installations.
Typical duty cycle is about 2 hours/day, with short frequent cycles. Daily energy falls around 3404 to 4784Wh depending on the model.
For well pumps, startup behavior matters more than nameplate HP. A soft-start design can change a borderline pairing into a stable one.
All 33 generators tested against the Well Pump (1 HP) (2392W / 7176W).
| Power Station | Running W | Surge W | Capacity | Weight | Verdict | Runtime | Report |
|---|---|---|---|---|---|---|---|
| Delta Pro Ultra X | 12,000 | 24,000 | 6,144 Wh | 187.4 lbs Two-person recommended | Safe | 1.8h | View |
| Delta Pro Ultra | 6,000 | 12,000 | 6,144 Wh | 182.1 lbs Two-person recommended | Safe | 1.8h | View |
| Anker SOLIX F3800 | 6,000 | 9,000 | 3,840 Wh | 132.3 lbs Two-person recommended | Safe | 1.1h | View |
| DELTA Pro 3 | 4,000 | 8,000 | 4,096 Wh | 113.5 lbs Two-person recommended | Tight | 1.2h | View |
| Zendure SuperBase V4600 | 3,800 | 3,800 | 4,608 Wh | 121.3 lbs Two-person recommended | Soft Start | 1.3h * | View |
| Yeti Pro 4000 | 3,600 | 7,200 | 3,993.6 Wh | 115.7 lbs Two-person recommended | Voltage Fail | N/A | View |
| Delta Pro | 3,600 | 7,200 | 3,600 Wh | 99.2 lbs Two-person recommended | Voltage Fail | N/A | View |
| Pecron E3600LFP | 3,600 | 7,000 | 3,072 Wh | 79.4 lbs Two-person recommended | Voltage Fail | N/A | View |
| Explorer 3000 Pro | 3,000 | 6,000 | 3,024 Wh | 63.9 lbs Two-person recommended | Voltage Fail | N/A | View |
| Elite 200 V2 | 2,600 | 3,600 | 2,073 Wh | 53.4 lbs Heavy carry | Voltage Fail | N/A | View |
| AC200L | 2,400 | 3,600 | 2,048 Wh | 62.4 lbs Two-person recommended | Voltage Fail | N/A | View |
| AC200MAX | 2,200 | 4,800 | 2,048 Wh | 61.9 lbs Two-person recommended | Voltage Fail | N/A | View |
| DELTA 2 Max | 2,400 | 4,800 | 2,048 Wh | 50.7 lbs Heavy carry | Voltage Fail | N/A | View |
| Explorer 2000 Plus | 3,000 | 6,000 | 2,042 Wh | 61.5 lbs Two-person recommended | Voltage Fail | N/A | View |
| Explorer 2000 v2 | 2,200 | 4,400 | 2,042 Wh | 39.5 lbs One-person carry | Voltage Fail | N/A | View |
| Yeti 1500X | 2,000 | 3,500 | 1,516 Wh | 45.6 lbs Heavy carry | Voltage Fail | N/A | View |
| DELTA (Gen 1) | 1,800 | 3,300 | 1,260 Wh | 30.9 lbs One-person carry | Voltage Fail | N/A | View |
| AC180 | 1,800 | 2,700 | 1,152 Wh | 36.2 lbs One-person carry | Voltage Fail | N/A | View |
| Explorer 1000 v2 | 1,500 | 3,000 | 1,070 Wh | 23.8 lbs One-person carry | Voltage Fail | N/A | View |
| SOLIX C1000 | 1,800 | 2,400 | 1,056 Wh | 28.4 lbs One-person carry | Voltage Fail | N/A | View |
| DELTA 2 | 1,800 | 2,700 | 1,024 Wh | 26.5 lbs One-person carry | Voltage Fail | N/A | View |
| DELTA 3 Plus | 1,800 | 3,600 | 1,024 Wh | 27.6 lbs One-person carry | Voltage Fail | N/A | View |
| VTOMAN Jump 1500X | 1,500 | 3,000 | 828 Wh | 36.2 lbs One-person carry | Voltage Fail | N/A | View |
| SOLIX C800 Plus | 1,200 | 1,600 | 768 Wh | 24.0 lbs One-person carry | Voltage Fail | N/A | View |
| AC70 | 1,000 | 2,000 | 768 Wh | 22.5 lbs One-person carry | Voltage Fail | N/A | View |
| RIVER 2 Pro | 800 | 1,600 | 768 Wh | 18.3 lbs Easy carry | Voltage Fail | N/A | View |
| Explorer 500 | 500 | 1,000 | 518.4 Wh | 13.2 lbs Easy carry | Voltage Fail | N/A | View |
| RIVER 2 Max | 500 | 1,000 | 512 Wh | 13.4 lbs Easy carry | Voltage Fail | N/A | View |
| SOLIX C300 | 300 | 300 | 288 Wh | 9.0 lbs Easy carry | Voltage Fail | N/A | View |
| Explorer 300 Plus | 300 | 600 | 288 Wh | 8.4 lbs Easy carry | Voltage Fail | N/A | View |
| EB3A | 600 | 1,200 | 268.8 Wh | 10.1 lbs Easy carry | Voltage Fail | N/A | View |
| RIVER 2 | 300 | 600 | 256 Wh | 7.7 lbs Easy carry | Voltage Fail | N/A | View |
| RIVER 3 | 300 | 600 | 245 Wh | 7.7 lbs Easy carry | Voltage Fail | N/A | View |
* Runtime with soft-starter installed. Without a soft-starter, these units cannot handle the startup surge.
28 of 33 generators tested cannot safely run this device. Here's why.
Voltage mismatch
This device requires 240V. 28 of 33 generators output a different voltage and cannot power it regardless of wattage.
Different models have different power requirements. Check the specific report for your exact model.
Out of 33 portable power stations we tested, 4 can safely run a Well Pump (3 with full safety margin, 1 at tight margin). 28 are incompatible.
Your power station needs at least 2,392W continuous output and 7,176W surge capacity at 240V split-phase. We recommend a safety buffer of 15% above these minimums for reliable operation.
Every pairing is evaluated using our True Surge protocol: we compare OEM-verified running watts, surge watts, and voltage requirements against each power station's published specs, with load-profile-specific safety buffers applied. Read our full methodology.
The startup profile. Two pumps with similar horsepower can have very different inrush behavior and therefore very different inverter compatibility.
Side-by-side comparisons for the top picks on this page.