Best Power Stations for Gas Furnace Fan (Blower)

We tested 33 portable power stations against the Gas Furnace Fan (Blower) (1058W running / 2430W surge). 22 passed our True Surge protocol — 67% compatibility rate.

Safe

20

Tight

2

With Soft-Starter

1

Incompatible

10

○ Device source: Engineering Est.

Derived from variant list (max of variants). Worst case running = Trane S8X1 B080 (1058W). Worst case surge = Goodman GMH8 080 (2430W). Running and surge maxima come from different variants due to ECM vs PSC motor technology.

Our Top Picks

Ranked by value, balance, and endurance from 20 compatible generators.

Best Budget Safe

VTOMAN Jump 1500X

Running 1,500W
Surge 3,000W
Capacity 828 Wh
Weight 36.2 lbs (16.4 kg)
Carry One-person carry
Runtime 0.5h
Best Overall Safe

Explorer 2000 Plus

Running 3,000W
Surge 6,000W
Capacity 2,042 Wh
Weight 61.5 lbs (27.9 kg)
Carry Two-person recommended
Runtime 1.4h
Best Runtime Safe

Delta Pro Ultra

Running 6,000W
Surge 12,000W
Capacity 6,144 Wh
Weight 182.1 lbs (82.6 kg)
Carry Two-person recommended
Runtime 4.1h

As an Amazon Associate, we earn from qualifying purchases. Our methodology

Runtime at a glance

How long each station runs a Gas Furnace Fan (Blower) on a single charge (after 0.70 real-world derate)

Safe

Showing top 8 by runtime. See full table below for all 23 stations (22 pass, 1 with soft-starter).

What to Know About the Gas Furnace Fan (Blower)

Power Profile

Running load: 810–1,058W depending on motor type (ECM vs PSC). Surge: 1,461–2,430W. Voltage: 120V AC required. The motor technology — ECM variable speed, ECM constant torque, or PSC multi-speed — determines both the running draw and the startup surge that your power station must handle.

Real-World Usage

Gas furnace blowers run 8+ hours per day during winter emergencies. ECM motors (Carrier, Trane) have controlled electronic startup. PSC motors (Goodman) create hard mechanical inrush at 3× running watts on every heating cycle. Daily energy ranges from 6,480–8,464 Wh.

Pro Tip

The blower motor is the only significant electrical load in a gas furnace — the gas burner itself uses negligible electricity. Check your furnace nameplate for motor type: ECM or constant torque means manageable surge; PSC or multi-speed means you need a power station rated for at least 2,500W surge.

Full Compatibility Matrix

All 33 generators tested against the Gas Furnace Fan (Blower) (1058W / 2430W).

Power Station Running W Surge W Capacity Weight Verdict Runtime Report
Delta Pro Ultra X 12,000 24,000 6,144 Wh
187.4 lbs
Two-person recommended
Safe 4.1h View
Delta Pro Ultra 6,000 12,000 6,144 Wh
182.1 lbs
Two-person recommended
Safe 4.1h View
Zendure SuperBase V4600 3,800 3,800 4,608 Wh
121.3 lbs
Two-person recommended
Safe 3h View
DELTA Pro 3 4,000 8,000 4,096 Wh
113.5 lbs
Two-person recommended
Safe 2.7h View
Yeti Pro 4000 3,600 7,200 3,993.6 Wh
115.7 lbs
Two-person recommended
Safe 2.6h View
Anker SOLIX F3800 6,000 9,000 3,840 Wh
132.3 lbs
Two-person recommended
Safe 2.5h View
Delta Pro 3,600 7,200 3,600 Wh
99.2 lbs
Two-person recommended
Safe 2.4h View
Pecron E3600LFP 3,600 7,000 3,072 Wh
79.4 lbs
Two-person recommended
Safe 2h View
Explorer 3000 Pro 3,000 6,000 3,024 Wh
63.9 lbs
Two-person recommended
Safe 2h View
Elite 200 V2 2,600 3,600 2,073 Wh
53.4 lbs
Heavy carry
Safe 1.4h View
AC200L 2,400 3,600 2,048 Wh
62.4 lbs
Two-person recommended
Safe 1.4h View
AC200MAX 2,200 4,800 2,048 Wh
61.9 lbs
Two-person recommended
Safe 1.4h View
DELTA 2 Max 2,400 4,800 2,048 Wh
50.7 lbs
Heavy carry
Safe 1.4h View
Explorer 2000 Plus 3,000 6,000 2,042 Wh
61.5 lbs
Two-person recommended
Safe 1.4h View
Explorer 2000 v2 2,200 4,400 2,042 Wh
39.5 lbs
One-person carry
Safe 1.4h View
Yeti 1500X 2,000 3,500 1,516 Wh
45.6 lbs
Heavy carry
Safe 1h View
DELTA (Gen 1) 1,800 3,300 1,260 Wh
30.9 lbs
One-person carry
Safe 0.8h View
Explorer 1000 v2 1,500 3,000 1,070 Wh
23.8 lbs
One-person carry
Safe 0.7h View
DELTA 3 Plus 1,800 3,600 1,024 Wh
27.6 lbs
One-person carry
Safe 0.7h View
VTOMAN Jump 1500X 1,500 3,000 828 Wh
36.2 lbs
One-person carry
Safe 0.5h View
AC180 1,800 2,700 1,152 Wh
36.2 lbs
One-person carry
Tight 0.8h View
DELTA 2 1,800 2,700 1,024 Wh
26.5 lbs
One-person carry
Tight 0.7h View
SOLIX C1000 1,800 2,400 1,056 Wh
28.4 lbs
One-person carry
Soft Start 0.7h * View
SOLIX C800 Plus 1,200 1,600 768 Wh
24.0 lbs
One-person carry
Fail N/A View
AC70 1,000 2,000 768 Wh
22.5 lbs
One-person carry
Fail N/A View
RIVER 2 Pro 800 1,600 768 Wh
18.3 lbs
Easy carry
Fail N/A View
Explorer 500 500 1,000 518.4 Wh
13.2 lbs
Easy carry
Fail N/A View
RIVER 2 Max 500 1,000 512 Wh
13.4 lbs
Easy carry
Fail N/A View
SOLIX C300 300 300 288 Wh
9.0 lbs
Easy carry
Fail N/A View
Explorer 300 Plus 300 600 288 Wh
8.4 lbs
Easy carry
Fail N/A View
EB3A 600 1,200 268.8 Wh
10.1 lbs
Easy carry
Fail N/A View
RIVER 2 300 600 256 Wh
7.7 lbs
Easy carry
Fail N/A View
RIVER 3 300 600 245 Wh
7.7 lbs
Easy carry
Fail N/A View

* Runtime with soft-starter installed. Without a soft-starter, these units cannot handle the startup surge.

Model Variants

Different models have different power requirements. Check the specific report for your exact model.

Carrier Infinity 59MN7A 080 (80,000 BTU)

Running: 886W
Surge: 1,461W
See compatibility report

Trane S8X1 B080 (80,000 BTU)

Running: 1,058W
Surge: 1,587W
See compatibility report

Goodman GMH8 0805B (80,000 BTU)

Running: 810W
Surge: 2,430W
See compatibility report

Frequently Asked Questions

How many power stations can run a Gas Furnace Fan (Blower)?

Out of 33 portable power stations we tested, 22 can safely run a Gas Furnace Fan (Blower) (20 with full safety margin, 2 at tight margin). 10 are incompatible.

What specs should I look for to run a Gas Furnace Fan (Blower)?

Your power station needs at least 1,058W continuous output and 2,430W surge capacity. We recommend a safety buffer of 15% above these minimums for reliable operation.

How do we test compatibility?

Every pairing is evaluated using our True Surge protocol: we compare OEM-verified running watts, surge watts, and voltage requirements against each power station's published specs, with load-profile-specific safety buffers applied. Read our full methodology.

What size power station do I need for a gas furnace blower?

Only if your power source can supply at least 1,058W continuous and 2,430W surge at 120V. PSC blower motors (common in builder-grade furnaces) create the highest startup demand. ECM motors in premium furnaces need less.